5. Weekly Schedule
This option assigns a programmed weekly schedule for each group when the selected group is automatically
switched On (Autoset) and Off (Autounset).
When the keyswitch is activated twice during the exit time of an autoset, the autoset is temporarily cancelled
for a few seconds, then it restarts the exit time causing the panel to reset.
Operating a keyswitch zone type during the pre-warn period of an autoset will start a Force Set. If you then
activate the switch again (i.e. unset with keyswitch) before the panel sets, the pre-warn continues on the
autoset.
NOTE: When the keyswitch is activated the second time to take panel back into pre-warn, it can be up to
10 seconds before the pre-warn tones at the keypad start up again.
Lockout
Each group can be allocated with up to 67 (dependent on panel variant) Lockout schedules over a seven day
period. These can be combined in any order of On and Off times as required.
If Lockout has been assigned to a group, the group is locked-out at the Lockout On time or when the group
sets - whichever occurs first. Outputs programmed as Lockout are active while the system is locked out - this
will not always correspond to the times assigned to the Lockout depending on whether the group sets prior to
Lockout On. When a group is locked-out the setting status indicates that it cannot be unset by displaying