Galaxy Dimension Installer Manual
Group Name Display
When viewing the groups assigned to an option, for example user code or outputs, simultaneously pressing the
# and
keys displays the groups individually. The keypad displays the group number, name and the status of
the particular option being displayed. Press the # key to toggle the status of the group. To move to another
group press the A or B keys or enter the number of the group directly.
Selected group
A or B key to move
to other group
Notes on Groups
1. All zones default to group 1.
2. All keypads, user codes and outputs default to all system groups assigned.
3. Remove unused groups from user codes, otherwise the unused groups will set and unset even though
they are not programmed.
4. Final, Keyswitch and Exit can be programmed to function in regard to other groups during the
setting and unsetting procedures (refer to option 52 = PROGRAM ZONES).
5. Outputs can be assigned to any selection of groups. Output activation can be made dependent on the
set or unset status of the assigned groups (refer to option 53 = PROGRAM OUTPUTS).
6
After programming zones, codes, keypads and outputs into their various groups they remain pro-
.
grammed if the Group Mode function is disabled. Only Group 1 remains active.
7. The Galaxy control panels have multi-user software that allow several users to operate the system
simultaneously.
A2 Sales Dept
A2 Sales Dept
A2 Sales Dept
A2 Sales Dept
A2 Sales Dept
[<],[>],#=CHANGE
[<],[>],#=CHANGE
[<],[>],#=CHANGE
[<],[>],#=CHANGE
[<],[>],#=CHANGE
# key to toggle status
6-163
63 - Options (cont'd)
Current group name
Status of group
S
S
S
S
S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents