42 - Codes (cont'd)
Default Codes
The Galaxy system provides four default codes: Manager, Engineer, Remote and Authorization User. Refer to
the following table:
Galaxy
No. of Codes
GD-48
100
GD-96
250
GD-264
1000
GD-520
1000
* The authorization code is a secondary system manager code but is not programmed by default.
Engineer Code
Engineer access is enabled via menu 48.1. This menu is only available to type 3.6 users.
The engineer code can only modify the engineer PIN.
The engineer code cannot assign, modify or delete the manager or user codes;
On accessing engineering mode, any group that is set becomes inaccessible to the engineer. The
set groups cannot be assigned to zones, outputs and any other functions permitting group
allocation;
While engineer mode is accessed, all tampers are disabled, however, all constantly alert zone
types — PA zone types, 24 Hour, Security, Fire — remain active.
The engineer banner is shown on all keypads while engineer mode is being accessed; the
message ENGINEER MODE is displayed;
Entry to the engineer mode must be authorized by a valid type 3.6 user (refer to option 48 = ACCESS
AUTHORIZATION). The engineer code must then be entered within five minutes of the option being ena-
bled. A single entry of the engineer code directly accesses engineer mode, without activating an engineer
tamper alarm; ENGINEER MODE is displayed on the keypad. If the engineer code is not entered within
the five minute period, the code is invalid and an Insufficient Access Rights message is displayed on the
keypad. Once the engineer mode has been accessed, there is no time limit on the period that the engineer can
remain in the mode.
NOTE: Dual entry of the engineer code in a system requiring user authorization does not give access to
engineer mode.
Manager
Default PIN
User No.
Default PIN
12345
98
12345
248
12345
998
12345
998
Table 6-4. Default Codes
Galaxy Dimension Installer Manual
Engineer
User No.
Default PIN
112233
99
543210
112233
249
543210
112233
999
54321
112233
999
543210
6-28
Remote
Authorization*
User No.
Default PIN
100
-
250
-
1000
1000
-
User No.
97
247
997
997