Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
MR-J3-_A_
No.
Name and function
PA08
Auto tuning mode
PA09
Auto tuning response
Make gain adjustment using auto tuning.
Auto tuning mode [Pr. PA08]
Select the gain adjustment mode.
0 0 0 x:
Gain adjustment mode setting
0: Interpolation mode (Automatically set parameter
No. [Pr. PB06/PB08/PB09/PB10])
1: Auto tuning mode 1 (Automatically set parameter
No. [Pr. PB06/ PB07/PB08/PB09/PB10])
2: Auto tuning mode 2 (Automatically set parameter
No. [Pr. PB07/PB08/PB09/PB10])
3: Manual mode
Note The parameters have the following names.
No.
Ratio of load inertia moment to servo
PB06
motor inertia moment
PB07
Model loop gain
PB08
Position loop gain
PB09
Speed loop gain
PB10
Speed integral compensation
Auto tuning response [Pr. PA09]
If the machine hunts or generates large gear sound,
decrease the set value. To improve performance,
e.g. shorten the settling time, increase the set value.
Guideline for
machine
Setting
Response
resonance
frequency [Hz]
Low
1
10.0
response
2
11.3
3
12.7
4
14.3
5
16.1
6
18.1
7
20.4
8
23.0
9
25.9
10
29.2
11
32.9
12
37.0
13
41.7
14
47.0
15
52.9
Middle
16
59.6
response
Initial
value
0001h
12
Name
Guideline for
machine
Setting
Response
resonance
frequency [Hz]
Middle
17
67.1
response
18
75.6
19
85.2
20
95.9
21
108.0
22
121.7
23
137.1
24
154.4
25
173.9
26
195.9
27
220.6
28
248.5
29
279.9
30
315.3
31
355.1
High
32
400.0
response
MR-J4-_A_
No.
Name and function
PA08
Same setting as MR-J3
Auto tuning mode
_ _ _ x:
Gain adjustment mode selection
Select the gain adjustment mode.
0: 2 gain adjustment mode 1 (interpolation mode)
1: Auto tuning mode 1
2: Auto tuning mode 2
3: Manual mode
4: 2 gain adjustment mode 2
Refer to table 2.2 for details.
Table2.2 Gain adjustment mode selection
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
PA09
Auto tuning response
Set a response of the auto tuning.
Setting range: 1 to 40
2 - 24
Control
Initial
mode
value
1h
P
S
0h
0h
0h
16
P
S