Mitsubishi Electric MELSERVO-J3 Series Manual page 304

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 5: Common Reference Material
No.
Symbol
PX22
NHQ5
Notch shape selection 5
Set the shape of the machine resonance suppression filter 5.
When you select "Enabled (_ _ _ 1)" of "Robust filter selection" in [Pr. PX31], the
machine resonance suppression filter 5 is not available.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PX23
*XOP
Function selection X-3
(Note)
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Note. MR-J4W2-_B servo amplifier is "for manufacturer setting".
Name and function
Explanation
Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
For manufacturer setting
Explanation
Torque limit function selection at instantaneous power
failure
(instantaneous power failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during
operation, you can save electric energy charged in the
capacitor in the servo amplifier by limiting torque at
acceleration. You can also delay the time until [AL. 10.2
Voltage drop in the main circuit power] occurs with
instantaneous power failure tough drive function. Doing
this will enable you to set a longer time in [Pr. PX28
SEMI-F47 function - Instantaneous power failure
detection time].
To enable the torque limit function at instantaneous
power failure, select "Enabled (_ 1 _ _)" of "SEMI-F47
function selection" in [Pr. PX25].
This parameter setting is used with servo amplifier with
software version B0 or later.
For manufacturer setting
5 - 119
Initial
Setting
value
range
[unit]
Refer to Name and
function column.
Initial
value
0h
0h
0h
0h
Refer to Name and
function column.
Initial
value
0h
0h
0h
0h
Each/
common
Each
axis

Hide quick links:

Advertisement

Table of Contents
loading