No.
Name and function
PC10
Analog monitor 2 output
Used to selection the signal provided to the analog monitor
2 (MO2) output.
_ 0 0 x:
Analog monitor 2 (MO2) output selection
The settings are the same as those of [Pr. PC09].
X 0 0 _:
Analog monitor 2 (MO2) output axis selection
The settings are the same as those of [Pr. PC09].
PC11
Analog monitor 1 offset
Used to set the offset voltage of the analog monitor 1
(MO1) output.
PC12
Analog monitor 2 offset
Used to set the offset voltage of the analog monitor 2
(MO2) output.
PC15
Station number selection
Used to select the axis to communicate with (SETUP221E).
0: A-axis
1: B-axis
PC17
Function Selection C-4
This parameter cannot be used in the speed control
mode and the torque control mode.
This is used to select a home position setting condition.
0 0 0 x:
Selection of home position setting condition
0: Need to pass motor Z-phase after the power supply is
switched on.
1: Not need to pass motor Z-phase after the power
supply is switched on.
PC18
This parameter is not used. Do not change the value.
MR-J3W-_B
Initial
No.
value
0001h
PC10
_ _ x x:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0
PC11
For manufacturer setting
0
PC12
For manufacturer setting
0000h
PC15
For manufacturer setting
0000h
PC17
Function selection C-4
Select a home position setting condition.
_ _ _ x:
Selection of home position setting condition
0: Need to pass servo motor Z-phase after power on
1: Not need to pass servo motor Z-phase after power on
_ _ x _ :
When a rotary servo motor is used, the setting does not
need to be changed.
_ x _ _ :
For manufacturer setting
x _ _ _ :
For manufacturer setting
0000h
PC18
Function selection C-5
Select an occurring condition of [AL. E9 Main circuit off
warning].
_ _ _ x:
For manufacturer setting
_ _ x _ :
For manufacturer setting
_ x _ _ :
For manufacturer setting
x _ _ _ :
[AL. E9 Main circuit off warning] selection
0: Detection with ready-on and servo-on command
1: Detection with servo-on command
4 - 36
MR-J4W2-_B
Name and function
Initial
value
01h
0h
0h
0
0
0
0h
0h
0h
0h
0h
0h
0h
0h