Part 5: Common Reference Material
No.
Symbol
PX26
OSCL1
Vibration tough drive - Oscillation detection level
Set a filter readjustment sensitivity of [Pr. PB13 Machine resonance suppression
filter 1] and [Pr. PB15 Machine resonance suppression filter 2] while the vibration
tough drive is enabled.
However, setting "0" will be 50%.
Example: When you set "50" to the parameter, the filter will be readjusted at the
time of 50% or more oscillation level.
PX27
*OSCL2
Vibration tough drive function selection
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PX28
CVAT
SEMI-F47 function - Instantaneous power failure detection time
Set the time until the occurrence of [AL. 10.1 Voltage drop in the control circuit
power].
This parameter setting range differs depending on the software version of the servo
amplifier as follows.
Software version C0 or later: Setting range 30 ms to 200 ms
Software version C1 or earlier: Setting range 30 ms to 500 ms
To comply with SEMI-F47 standard, it is unnecessary to change the initial value
(200 ms).
However, when the instantaneous power failure time exceeds 200 ms, and the
instantaneous power failure voltage is less than 70% of the rated input voltage, the
power may be normally turned off even if a value larger than 200 ms is set in the
parameter.
To disable the parameter, set "Disabled (_ 0 _ _)" of "SEMI-F47 function selection"
in [Pr. PX25].
PX29
DRAT
Drive recorder arbitrary alarm trigger setting
Setting
digit
_ _ x x
x x _ _
Setting example:
To activate the drive recorder when [AL. 50 Overload 1] occurs, set "5 0 0 0".
To activate the drive recorder when [AL. 50.3 Thermal overload error 4 during
operation] occurs, set "5 0 0 3".
Name and function
Explanation
Oscillation detection alarm selection
0: [AL. 54 Oscillation detection] will occur at oscillation
detection.
1: [AL. F3.1 Oscillation detection warning] will occur at
oscillation detection.
2: Oscillation detection function disabled
Select alarm or warning when an oscillation continues at
a filter readjustment sensitivity level of [Pr. PX26].
The digit is continuously enabled regardless of the
vibration tough drive in [Pr. PX25].
For manufacturer setting
Explanation
Alarm detail No. setting
Set the digits when you execute the trigger with arbitrary
alarm detail No. for the drive recorder function.
When these digits are "0 0", only the arbitrary alarm No.
setting will be enabled.
Alarm No. setting
Set the digits when you execute the trigger with arbitrary
alarm No. for the drive recorder function.
When "0 0" are set, arbitrary alarm trigger of the drive
recorder will be disabled.
5 - 121
Initial
Setting
value
range
[unit]
50
0
[%]
to
100
Refer to Name and
function column.
Initial
value
0h
0h
0h
0h
200
30
[ms]
to
500
Refer to Name and
function column.
Initial
value
00h
00h
Each/
common
Each
axis
Each
axis
Common
Common