DIP Switch Settings
DIP switch 2
1
2
MODE 2
Pin 1 Slave communication mode setting
1
0
Pin 1 Setting
Pin 6 Setting
Use the connector provided as an accessory as the communications connector.
The user must provide the connecting cable. If a connector other than the acces-
sory connector is to be used, see the list of applicable connector model numbers
at the end of this manual.
3 4 5 6 7 8
Communication speed priority setting
Communication distance priority setting
Pin 1 setting is effective only when the user has access to a EEPROM DC (with
no battery). Pin 1 setting has nothing to do with a SRAM DC (with a built-in bat-
tery). Refer to R/W Head and Data Carrier Operation Manuals for details.
When selecting the 1 to N procedure on the V600-CA1A-V
Interface, N must be 1. In this case, it is possible to add a check code FCS.
Pin 8 (V600-CA2A-V
only)
Termination resistor connected (ID
1
Controller transmission side)
0
Termination resistor not connected
Pin 7 (V600-CA2A-V
only)
Termination resistor connected (ID
1
Controller transmission side)
0
Termination resistor not connected
Pin 6
1
1 to N procedure
1 to 1 procedure
0
ID Controller unit number settings
Pin 2
Pin 3
Pin 4
Pin 5
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
Ensure that there is no duplication of unit number.
Section
5-4
Unit No.
Unit 0
Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Unit 11
Unit 12
Unit 13
Unit 14
Unit 15
and RS-232C
85