Omron V600 Series Operation Manual page 46

Serial interface id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Command Types and Responses
3-4-8 Management Data Check (MD C/K)
1 to 1 Procedure
Command Format
Processing specification
(C for collation and K for calculation)
R/W Head No. designation
Start address number
Response Format
1 to N Procedure
Command Format
@
Unit
00 to 15
Processing speed
(C for collation and K for calculation)
R/W Head No. designation
Start address number
Response Format
@
Unit
00 to 15
44
This command makes it possible to write or collate the CRC code in a check
block that the user designates. The CRC code is calculated using the formula
16
12
5
X
+ X
+ X
+ 1 (refer to 3-2-5 DC Memory Check Function ).
M
D
C/K
1/2
X
M
D
0
0
M
D
C/K
1/2
No.
M
D
0
0
No.
Note The number of check block bytes required is the bytes of the check code calcula-
tion area plus two bytes. Refer to 3-2-5 DC Memory Check Function for details.
X
X
X
X
X
*
s
End code
00: Normal response (for calculation processing time only)
75: Normal data (for collation processing time only)
76: Warning code (for collation processing time only)
X
X
X
X
X
FCS
End code
00: Normal response (for calculation processing time only)
75: Normal data (for collation processing time only)
76: Warning code (for collation processing time only)
Section
*
s
Check block byte number in HEX
(hexadecimal) code
[03H, 04H, ..., 00H (256 bytes)]
X
FCS
Check block byte number in HEX
(hexadecimal) code
(03H, 04H, ..., 00H (256 bytes) )