Communications Program Example
3-6
Communications Program Example
3-6-1 Serial System Link to Host Computer
System Configuration Example (1 to 1 Procedure)
BASIC Program Example
10
CLS
20
OPEN "COM1:9600, E, 8, 1, CSO, DSO, CDO, PE" AS #1
30
WIDTH #1,255
40
PRINT "EXECUTING WRITE COMMAND"
50
INPUT "WRITE ADDRESS (HEX DATA:0006 TO 07FF)"; WA$
60
INPUT "WRITE DATA (HEX DATA:2-CHARACTER UNITS)"; WD$
70
TX$="WTH1"+WA$+WD$+"*"+CHR$(&HD)
80
PRINT TX$
90
PRINT #1, TX$;
100 INPUT #1, RX$
110 PRINT "RS DATA=";RX$
120 GOTO 40
3-6-2 Example of Basic Program with Host Computer's Time-up
Functions
System Configuration
BASIC Program Example
10
OPEN "COM1:9600,E,8,1,CS0,DSO,CDO,PE" AS#1
20
NG=0:1=0:CNT=0:PRINT
40
T$="@00TS0123456789ABSDEF"
50
GOSUB*FCSSET
70
TXD$=T$+FCS$+"*"
50
RS-232C
This is an example of a program that uses write commands to write data from the
DC Head 1 in hexadecimal code. Specify the write address in the range 0006
07FF
, and the write data in two-character units, up to 256 characters. Be sure
H
to correctly set the ID Controller communications format by setting its DIP
switches to conform to the communications format with the host computer to
which it is connected.
Note Above BASIC Program is for use with an IBM PC/AT or compatible computer.
RS-232C
RS-422
B500-AL004 (-P)
Link Adapter
. . . . . . . . . . . . . . . . . . . . . . . . . . .
V600-CA2A-V
RS-232C open
. . . . . . . .
Test data
Section
3-6
to
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca1a-v seriesV600-ca2a-v seriesV600-h seriesV600-d seriesV600-ca1a-v2V600-ca2a-v2 ... Show all

Table of Contents