Omron V600 Series Operation Manual page 51

Serial interface id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

V600-CAjA-Vj ID Controller
2-1
V600-CA A-V
2-1-1 Nomenclature
Front Panel
Operation indicators
Operation Indicators
Terminal Connections
8
ID Controller
Reset input terminals
Error output terminals
Note Where there is no reference to the "V600-CA1A-V
"V600-CA2A-V
Name
POWER (green)
HEAD 1 (green)
HEAD 2 (green)
ERROR (red)
STOP (red)
Name
100 to 240 VAC
GR
RESET/COM
ERROR
!
!
Open terminals (do not use)
only" is given, all information in this section is common to both.
Lit when power is applied.
Lit when R/W Head 1 is communicating.
Lit when R/W Head 2 is communicating.
Lit when an ID Controller operation stop error (CPU error,
memory error) is detected, or when an error in communications
with an IBM PC/AT or compatible or with R/W Heads is
detected. Error messages can be read from the host computer
or Monitor Unit.
Lit when an operation stop error (CPU error, memory error)
occurs, or when an external reset input is received.
Connection for the 100 to 240 VAC (50/60 Hz) power supply.
Protective conductor terminal. Connect a dedicated ground
cable here and ground at a resistance of less than 100 Ω.
Emergency stop external reset input. Use a 24-VDC power
supply.
External output terminal for error signals when an operation
stop error is detected. Connect via a 24-VDC relay or similar
device.
Section
Protective conductor terminal
Power supply terminals
Monitor Unit connector
V600-CA A-V
ID Controller
only" or the
Description