Wiring Procedures
Error Signal Output Wiring
5-3-3 Removing Terminal Cover
Lay the input line away from high-voltage equipment or power lines to improve
noise resistance of the lines.
The output section maximum switching capacity is 100 mA at 24 VDC (+10%,
–15%). Applying voltages or loads that exceed the switching capacity will dam-
age the equipment.
It is recommended that auxiliary relays (100 mA max. at 24 VDC) be used in
the output circuit.
Note The reset signal input terminal and error signal output terminal will be supplied
from an SELV source in accordance with IEC1010-1 Annex I-I.
The terminal cover must be removed with a slotted-head screwdriver in the
direction (A).
Slotted-head screwdriver
+
Reset input
24VDC
!
!
+
24VDC
To error output
(A)
Section
5-3
Terminal cover
81