Omron V600 Series Operation Manual page 67

Serial interface id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Data Read and Write Operations
1, 2, 3...
64
Data read by the read operation contains the job specification head and page
numbers. If the start address is not set, the data in address 00 is read.
1. When the READ Key is pressed, "RD" (read operation) appears on the dis-
play, and the data in the specified address is shown at the right end of the
display. If the READ Key is pressed again, the address is incremented, and
the next data can be read.
Note If no R/W Head is connected, if the DC is not in the communications
range, or if a communication error occurs, an error code is displayed
(see page 97). When this happens, use the horizontal cursor keys to
display the error message.
2. Use the INC/DEC Key to increment or decrement the address, and then
press the READ Key to read the data. To read data from an address of a
different page, start the procedure from the job specification.
Note
1. If the INC/DEC Key is pressed, and the address exceeds the 00 to FF range:
00
Page 2
INC
FF
2. If the address is FF when the INC Key is pressed, the setting returns to
address 00 of the same page.
3. If the address is 00 when the DEC Key is pressed, the setting moves to
address FF of the same page.
00
Page 2
DEC
FF
Section
4-4