Omron V600 Series Operation Manual page 59

Serial interface id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Using Monitor Unit (V600-P01)
Operation Keys
4-1-4 Preparations for Operations in Monitor Mode
Operation
Setting
JOB
Head no.
specification
(HEAD)
Page no.
(PAGE)
ADRS,
Start
address
address
(a)
End
address
(a)
DATA (d)
JOB Specification
ADRS (Address) Settings
DATA setting
56
These are used to select functions and execute operations and also include
numerical keys.
Key Designations
Function selection
JOB
ERR
TEST
Operation
WRITE
WRITE
READ
1
2
Numbers
to
o
F
English/Japanese Character Selection
or
Note There is a beeper in the ID Controller, which activated when a mistake is made in
the Monitor Unit key operations, or when read or write operations cannot be per-
formed (because DC is not present or other reasons).
The following information provides the relationships between various settings
before the execution of read, write, or test operations in the MONITOR Mode.
Read
WRITE 1,
stepped
write
Setting
Setting
required
required
Setting
Setting
required
required
Setting
Setting
required
required
(see note
2)
---
---
---
Setting
required
The job specification includes the specifications of the R/W Head numbers and
page numbers required for all read or write operations.
This requires setting the start address (a) and the end address (a). It is extremely
important to ensure that the start address does not exceed the end address. If it
does, only the start address will be effective.
For a write operation, one byte of the specified data is written to the DC in the
area defined by the start and end addresses.
ADRS
DATA
DEC
INC
SET
PESET
WRITE 2,
Test read
continu-
ous write
Setting
Setting
Setting
required
required
required
Setting
While
While
required
significant,
significant,
setting can
setting can
be omitted
be omitted
(see note
(see note
1)
1)
Setting
While
While
required
significant,
significant,
(see note
setting can
setting can
2)
be omitted
be omitted
(see note
(see note
1)
1)
Setting
While
While
required
significant,
significant,
(see note
setting can
setting can
2)
be omitted
be omitted
(see note
(see note
1)
1)
Setting
---
---
required
Section
Test, auto
Test write
read
Setting
Setting
required
required
Setting
Setting
required
required
Setting
Setting
required
required
(see note
(see note
2)
2)
Setting
Setting
required
required
(see note
(see note
2)
2)
Setting
Setting
required
required
4-1
Test auto
write

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca1a-v seriesV600-ca2a-v seriesV600-h seriesV600-d seriesV600-ca1a-v2V600-ca2a-v2 ... Show all

Table of Contents