Command Types and Responses
3-4-2 Write (WT)
Command Format
For 1 to 1 Procedure
Write
W.
Header
ASCII/HEX code specification
A: ASCII code
H: HEX code
5/ R/W Head no.
Start address no. specification range
For 1 to N Procedure
Write
@. Unit No.
W
00 to 15
Header
ASCII/HEX code specification
A: ASCII code
H: HEX code
R/W Head no.
Start address no. specification range
Response Format
36
Data is written to the DC. If the DC is not present, an error response (end code:
72 = DC not present) is returned.
1 frame = 266 characters max.
T
A/H. 1/2
X
X
1 frame = 271 characters max.
T
A/H
1/2
X
X
For 1 to 1 Procedure
W
T
Write
Header
For 1 to N Procedure
Write
@. Unit No.
00 to 15
Header
X
X
X
X
X
Specifies the write data.
*The number of bytes that can be written in one operation is
as follows:
ASCII code specification: 256 bytes (256 characters)
HEX code specification: 128 bytes (256 characters)
(When specifying HEX code, specify one byte as two charac-
ters.)
X
X
X
X
X
Specifies the write data.
*The number of bytes that can be written in one operation is as
follows:
ASCII code specification: 256 bytes (256 characters)
HEX code specification: 128 bytes (256 characters)
Note: Refer to the previous page for information on the set-
ting values.
0
0
End code (see page 48)
00: Normal completion
W
T
0
0
Section
.......
X
FCS
.......
X
FCS
End code (see page 48)
00: Normal completion
3-4