Omron V600 Series Operation Manual page 64

Serial interface id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Basic Operations
1, 2, 3...
4-3-3 Address Setting (ADRS)
Operation Procedure
The JOB Key is effective when the MONITOR Mode initial display is shown.
Press the RESET Key to move from another operation and create the job specifi-
cation.
1. When the JOB Key is pressed, "HEAD1" is displayed. If R/W Head 1 is to be
set, press the SET Key. If R/W Head 2 is to be set, press the INC/DEC Key
once and then press the SET Key.
2. When the Set Key is pressed, "page0" is displayed.
3. Press the INC Key twice and specify page 2.
4. Press the SET Key to set the page number to 2, and then the display chan-
ges to address/data.
Note
1. The head number is specified using the INC/DEC Key. The numerical keys
are not effective.
2. A page number is the number of a division in the DC memory area (see page
21).
DC memory area
0000
to
Page 0
00FF
0100
to
Page 1
01FF
to
0700
Page 7
to
07FF
This enables the setting of the start address for data reading, writing, and test-
ing.
Start address: 5A in this example
RESET
ADRS
5
A
INC
INC
DEC
DEC
256 bytes
256 bytes
2048 bytes
256 bytes
aXXdXX
a_ dXX
a5_dXX
a5AdXX
a5AdXX
a5AdXX
Section
4-3
(1)
(2)
(3)
(4)
61