Check Inlet Pressure; Reassemble Of Fire & Log Set Layout; Fitting The Burner Unit Into Convector Box; Fitting The Top Tray Onto The Burner Unit - Valor Inspire L Installer And Owner Manual

Table of Contents

Advertisement

INSTALLER GUIDE

14.6 Check inlet pressure.

The appliance is pre-set to give the correct heat input
at the inlet pressure shown in section 4 of this guide.
1. Ensure that the fire is OFF then fit a pressure
gauge at the test point. The test point is on the inlet 'T'
connector. Turn the fire ON and check the pressure
with the appliance alight and set at maximum output.
2. After checking, turn off the appliance. Remove the
pressure gauge and replace the test point sealing
screw.
3. Test around the sealing screw for gas soundness
with a suitable leak detection fluid.
15. REASSEMBLE OF FIRE & LOG SET LAYOUT
The remaining parts that where removed earlier now need to be refitted;
15.1 Secure the burner unit into the convector box using the screws removed earlier.
15.2 The top tray requires screwing back in position.
15.3 Install the log set and decorative components supplied
15.3.1 Fit the 4 small logs as shown in the picture. Two fit at the rear and the other
two at the front running back between the 3 burner tubes.
©
Page 29
GDC Group Ltd. SEPT 2018

Hide quick links: