Regularly inspect the air filter. A dirty air filter restricts airflow in the unit, producing a negative effect
on the ventilation of the chassis. The filter degrades over time. You must replace the filter every 6
months.
CAUTION:
the fans are very powerful, they could pull small bits of wire or other materials into
the through the unfiltered air intake. This could damage the components.
The shelf life of polyurethane filter varies from two years to five years depending on the storage
conditions. Store in a cool, dry, and dark environment. Wrap the media in plastic and store in an
environment with relative humidity between 40%- 80% and temperature between 40° F (4° C) to 90° F
(32° C). Note that if the material flakes, or becomes brittle when rubbed or deformed, it is no longer
usable.
SEE ALSO
MX10003 Cooling System Description | 31

Replacing the MX10003 Air Filter Unit

IN THIS SECTION
Removing the MX10003 Air Filter Unit | 118
Installing the MX10003 Air Filter Unit | 118
The air filter unit consists of three parts–the outer filter cover, the air filter, and the inner cage which forms
the body, and the air filter. The air filter sits right inside the outer filter cover and the inner cage. The air
filter unit is installed into the cable management brackets, and are held tightly by captive screws.
Always keep the air filter in place while the device is operating. Because