Maintaining Mpcs - Juniper MX10003 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX10003:
Table of Contents

Advertisement

Figure 50: Installing a MIC
SEE ALSO
Routine Maintenance Procedures for MX10003 Routers | 116
Prevention of Electrostatic Discharge Damage | 182

Maintaining MPCs

Purpose
The router can have up to two MPCs mounted horizontally in the card cage at the front of the chassis.
For optimum router performance, verify the condition of the MPCs.
Action
On a regular basis:
Check the OK/FAIL LED on the MPC. If the MPC detects a failure, the MPC sends an alarm message to
the Routing Engine.
Issue the show chassis fpc CLI command to check the status of installed MPCs. As shown in the sample
output, the value Online in the column labeled State indicates that the MPC is functioning normally:
user@host> show chassis fpc
Utilization (%)
Slot State
Heap
Buffer
0
Online
12
11
1
Online
12
11
Temp
CPU Utilization (%)
(C)
Total
Interrupt
57
24
58
20
CPU Utilization (%)
1min
5min
0
21
23
0
21
23
Memory
15min
DRAM (MB)
23
3136
23
3136