GENERATOR NO-LOAD PERFORMANCE
• Remove the front seat. (8-3)
• Disconnect the generator coupler.
• Start the engine and keep it running at 5 000 r/min.
• Using the multi circuit tester, measure the voltage between
three lead wires.
If the tester reads under the specified value, replace the gen-
erator with a new one.
 Generator no-load performance:
60 V and more at 5 000 r/min (When engine is cold)
 09900-25008: Multi circuit tester set
 Tester knob indication: Voltage (~)
REGULATOR/RECTIFIER
• Disconnect the regulator/rectifier coupler 1 and remove the
regulator/rectifier 2.
• Measure the voltage between the lead wires using the multi
circuit tester as indicated in the table below. If the voltage is
not within the specified value, replace the regulator/rectifier
with a new one.
 09900-25008: Multi circuit tester set
 Tester knob indication: Diode test ()
+ Probe of tester to:
R
R
B
1
B
2
B
3
B/W
1.4 V and more (tester's battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are
not connected, replace its battery.
B
B
B
1
2
0.1 – 0.8
0.1 – 0.8
0.1 – 0.8
Unit: V
B/W
3
0.4 – 1.1
0.1 – 0.8
0.1 – 0.8
0.1 – 0.8