In figure 41, the commands executed by the IPL T S2 in response to SSI references have
been replied to, and were implemented when the web page was served to the browser.
Figure 41.
Browser View of Previous HTML Source Code
Example 2
The example below shows how a simple hyperlink and a remote query string can be used to
build a web page that can control a device.
<html>
<head><title>Example 2</title></head>
<h2><b>HTML Example 2</b></h2>
<body>
The following lines demonstrate how to send commands to RS-232
Comm Port #1 of an IPLink Product:
<p>
<a href="index.html?cmd=W01RS|1!">Select Input #1</a>
<br>
<a href="index.html?cmd=W01RS|2!">Select Input #2</a>
</p>
</body>
</html>
Figure 42.
HTML Source Code Showing Multiple Hyperlinks Using Query Strings
Figure 43.
Browser View of Previous HTML Source Code
NOTE: Before attempting to develop new web pages, the user should have a working
knowledge of JavaScript, HTML, and SSI.