Mode Activation
1
Hold down the recessed Reset
button while applying power to
the IPL T S unit.
NOTE:
After a mode 1 reset
is performed, update the
unit firmware to the latest
version. Do not operate the
unit firmware version that
results from the mode 1
reset. If you want to use the
factory default firmware, you
must upload that version
again.
2
Press and release the Reset
button. Within 2 seconds type
+++ on the keyboard.
NOTE:
If the three
+++
(
) are not entered in
the 2-second time frame,
the COM port becomes a
control port only.
3
Hold down the Reset button for
about 3 sec. until the Reset LED
blinks once.
Then press Reset momentarily
(<1 sec.) within 1 second.
4
Hold down the Reset button for
about 6 seconds. until the Reset
LED has blinked twice (once at 3
seconds, again at 6 seconds).
Then press Reset momentarily
(for <1 second) within 1 second.
5
Hold down the Reset button for
about 9 sec. until the Reset LED
has blinked three times (once at
3 seconds, again at 6 s seconds,
again at 9 seconds).
Then press Reset momentarily
(for <1 second) within 1 second.
Reset Mode Comparison/Summary
Results
The unit reverts to the factory default firmware.
Event scripting will not start if the unit is powered
on in this mode. All user files and settings (drivers,
adjustments, IP settings, and so forth) are maintained.
NOTE:
If you do not want to update firmware, or
you performed a mode 1 reset by mistake, cycle
power to the unit to return to the firmware version
that was running prior to the mode 1 reset. Use
the 0Q SIS command to confirm that the factory
default firmware is no longer running (look for
asterisks following the version number.)
The connected COM port becomes a console port to
send SIS commands. Scripting remains on.
+
signs
Mode 3 turns events on or off.
During resetting, the Reset LED flashes 2 times if
events are starting, 3 times if events are stopping.
Enables ARP capability.
Sets the IP address back to factory default
(192.168.254.254).
Sets the subnet back to factory default.
Sets the default gateway address back to the
factory default.
Sets port mapping back to factory default.
Turns DHCP off.
Turns events off.
The Reset LED flashes 4 times in quick succession
during the reset.
Mode 5 performs a complete reset to factory defaults
(except the firmware).
Does everything mode 4 does.
Resets almost all the real time adjustments: all
audio settings, limit initial power up volume, power
up/down delay, auto power down, and misc.
options. This does not affect an optional MLS
switcher, however.
Clears driver-port associations and port
configurations (IR/RS-232).
Removes button configurations.
Resets all IP options.
Removes scheduling settings.
Removes/clears all files from switcher.
The Reset LED flashes 4 times in quick succession
during the reset.
Purpose
Use mode 1 to revert to the
factory default firmware version if
incompatibility issues arise with
user-loaded firmware.
Mode 2 enables the SIS console
port.
Mode 3 is useful for
troubleshooting.
Mode 4 enables you to set IP
address information using ARP
and the MAC address.
Mode 5 is useful if you want to
start over with configuration and
uploading, and also to replace
events.
IPL T S Series • Installation and Operation