Port Settings
The Port Settings page grants access to view or change the Serial Port Settings:
Serial port number — use a radio button to select the desired port
Port type — RS-232 (default), RS-422, 4S-485
Baud rate — 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600 (default), 14400,
19200, 28800, 38400, 57600, 115200
Parity — 7, 8 (default)
Stop bits — 1 (default), 2
Flow control — None (default), Hardware, Software
Serial Bridging — On, Off (default)
Remote IP Address — view the remote IP address
Remote TCP Port — view the remote TCP port
Figure 28.
Port Settings Screen
Passwords
NOTE: The factory configured passwords for all accounts on this device have been set
to the device serial number. In the event of an absolute system reset, the passwords
convert to the default, which is no password.
The Passwords page fields include:
Administrator Password — provides complete configuration control
User Password — allows view of configuration only
Figure 29.
Passwords Screen
To clear a password, enter a single space, repeat the entry in the re-enter password field,
then click the Submit button.
If no administrator password is present, the user password is not saved.