Troubleshooting and tips
SCSI configuration incorrect (Ultra Wide SCSI Controller)
Ê In the SCSI configuration menu, check the settings for the hard disk drives
( SCSI Device Configuration ) and the settings under Advanced Configuration
Options .
7.10

Drives are reported as "dead"

This error message may occur when the server has a disk array controller:
SCSI cabling incorrect
Ê Make sure the SCSI cable connection and the SCSI channel assignment still
correspond to the original state.
The disk array controller configuration is incorrect
Ê Check and correct the settings for the drives with the RAID configuration
program.
Further information is provided in the manual for the disk array controller.
7.11

Added drive reported defective

This error message may occur when the server has a disk array controller.
Disk array controller is not configured for this hard disk drive
The drive was probably installed with the system switched off.
Ê Reconfigure the disk array controller for the hard disk drive. Information is
contained in the documentation for the disk array controller.
or
Ê Reinstall the drive while the system is switched on.
If the hard disk drive continues to be shown as defective, then replace it (see
section "SCSI hard disk subsystem" on page 64).