Summary of Contents for Fujitsu PRIMERGY BX600 S2

  • Page 1: Primergy Bx600 S2 Basic Unit

    PRIMERGY BX600 S2 Basic Unit Operating Manual Edition March 2007...
  • Page 2: Copyright And Trademarks

    Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2007 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Instructions on Connecting and Disconnecting Cables ..45 Connecting the System to the Mains ... . . 46 PRIMERGY BX600 S2 Basic Unit ... 19 .
  • Page 4 BIOS Setup Security Functions Server Blades ......71 Installation Sequence ..... . 73 Adding a Server Blade to the Basic Unit .
  • Page 5 13.3 Digital KVM Blade ..... . . 137 PRIMERGY BX600 S2 Basic Unit Contents ....100 .
  • Page 6 Time and Date Are Not Correct ....159 16.10 Server Blade Does Not Boot ....159 16.11 Defective Drive .
  • Page 7: Introduction

    19-inch rack systems. Figure 1: PRIMERGY BX600 S2 Basic Unit The PRIMERGY BX600 S2 basic unit occupies seven height units in the rack and can accommodate up to ten server blades of different models and configu- rations.
  • Page 8: Overview Of The Documentation

    This operating manual is intended for those responsible for installing the hardware and operating the system. The manual contains all the information required for mounting and operating your PRIMERGY BX600 S2 basic unit. For a brief overview of the installation steps please see chapter...
  • Page 9 – „PRIMERGY BX Blade Server Systems: RemoteView Management Blade - User Interface Description“ (PDF-Version auf ServerBooks-DVD enthalten) – „PRIMERGY BX Blade Server Systems: LAN Switch Blade - User Interface Description“ (PDF-Version auf ServerBooks-DVD enthalten) – „PRIMERGY BX Blade Server Systems: Cisco Catalyst Blade Switch 3040 - Hardware Installation Guide“...
  • Page 10: Features

    165. Communication interfaces The PRIMERGY BX600 S2 basic unit has four slots on the back for installing different types of communication blades which allow the installed server blades to be connected to the Ethernet LAN or to SAN environments. The connections can be implemented via switch blades and/or pass-thru blades.
  • Page 11 The Ethernet LAN Pass-Thru-Blade has ten RJ45 connectors. Fibre Channel pass-thru blade The PRIMERGY BX600 S2 basic unit can have one or two Fibre Channel pass-thru blades to provide Fibre Channel functionality for the installed server blades. A Fibre Channel (FC) pass-thru blade offers 10 ports for bypass connections between FC daughter cards installed in the server blades and the optical transceivers for serial FC I/O and general I/O signals.
  • Page 12 Features KVM-Blade For administering the server blades, the PRIMERGY BX600 S2 basic unit offers a KVM blade, which allows the individual server blades to be connected to a console. – The standard KVM blade allows a monitor, PS2 keyboard and PS2 mouse to be connected for local administration of the server blades.
  • Page 13 Introduction Server Management Server management is implemented via the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers. PDA warns of system errors or overloading before they occur so that preventive measures can be taken.
  • Page 14: Notational Conventions

    Notational Conventions The flash EPROM program supplied with the Fujitsu Siemens utilities supports fast BIOS update. The two redundant and hot-swappable management blades with independent management LAN and COM ports ensure complete remote control. Together they facilitate remote diagnosis for system analysis, remote configuration and remote restart, should the operating system or hardware fail.
  • Page 15: Technical Data

    Noise immunity CE label according to EU directives Certification Product safety Global PRIMERGY BX600 S2 Basic Unit 200 - 240 V 50 Hz - 60 Hz 230V / 11,6 A 230 V / 2650 W 2680 VA (230V) 2050 kJ/h...
  • Page 16 Technical Data Europe Germany USA/Canada Japan Mechanical Values Width Installation depth Height Weight max. 131.5 kg (depending on the configuration) ENEC / CSA VCCI 446 mm 740 mm 307 mm oder 7 HE PRIMERGY BX600 S2 Basic Unit Introduction...
  • Page 17 Condensation during operation must be avoided. Noise Level Sound power level L Sound pressure level at bystander position (ISO 9296) PRIMERGY BX600 S2 Basic Unit DIN IEC 721 section 3-3 DIN IEC 721section 3-2 5 ºC ... 35 ºC -20 °C ... 60 °C 10%...85%...
  • Page 19: Overview: Basic Unit Installation Steps

    BX600 S2 basic unit (see chapter page 49). Ê Insert the server blades into the slots in the front of the BX600 S2 basic unit (see chapter 7 on page Ê Configure the management blades (see section can perform further administration of the blade server system via LAN.
  • Page 20 If you wish to install an operating system that is not supported by Server- Start, you can perform the installation directly without using ServerStart. For further information on remote or local installation of server blades, please see the ServerStart manual, which contains a “Quick Step...
  • Page 21: Important Notes

    If you have any questions, please contact your sales outlet or the customer service center of Fujitsu Siemens Computers. CAUTION! The actions described in these instructions should only be performed by technicians, service personnel or technical specialists.
  • Page 22 (public) power supply networks for the type-A connector. For the PRIMERGY BX600 S2 basic unit only 2100W PSUs are allowed (Product no. A3C40073262)! The 1200W PSUs of the PRIMERGY BX600 S1 basic unit is not allowed for the PRIMERGY BX600 S2 basic unit.
  • Page 23 Important Notes Make sure that the PRIMERGY BX600 S2 basic unit is connected to the mains for at least one minute before pressing the power ON/OFF button to switch the system ON. CAUTION! The server automatically adjusts to a mains voltage of 200 - 240 V.
  • Page 24 Pb Lead Other Important Notes: Keep this operating manual and all additional documentation together with the device. If you pass on the device to third parties, you should also pass on the complete documentation. Important Notes PRIMERGY BX600 S2 Basic Unit...
  • Page 25: Components With Electrostatic-Sensitive Devices

    The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC “Electromagnetic compatibility” and 73/23/EEC “Low voltage directive”. The device therefore qualifies for the CE certificate (CE=Communauté Européenne). PRIMERGY BX600 S2 Basic Unit Components With Electrostatic-Sensitive Devices...
  • Page 26: Fcc Class A Compliance Statement

    Consult the dealer or an experienced radio/TV technician for help. Fujitsu Siemens Computers is not responsible for any radio or television inter- ference caused by unauthorized modifications of this equipment or the substi- tution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers.
  • Page 27: Transporting The Basic Unit

    Transporting the Basic Unit CAUTION! Transport the PRIMERGY BX600 S2 basic unit only in its original packaging or in a packaging which protects it from knocks and jolts. Do not unpack the basic unit until you have finished transporting it.
  • Page 28: Notes On Installing In The Rack

    For lifting the basic unit, use the handles on the front and the fold-out handles on the long sides of the chassis. Before lifting the basic unit into the rack, remove server blades, fan units and power supplies from the system unit to reduce weight.
  • Page 29: Environmental Protection

    Environmental Protection Environmental Protection Environmentally Friendly Product Design and Development This product has been designed in accordance with the Fujitsu Siemens Computers standards for ”environmentally friendly product design and devel- opment“. This means that the designers have taken into account important...
  • Page 30 Electrical (electronic) devices which are marked with one of the following symbols may not be disposed of with household refuse in accordance with the EU directive. Figure 3: Symbols for electrical (electronic) devices Important Notes “Local Contacts” on PRIMERGY BX600 S2 Basic Unit...
  • Page 31 Local Contacts For details on take-back and reuse of devices and consumables within Europe, contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 33: Installing The Hardware

    Installing the Hardware CAUTION! Please note the safety instructions in the page Do not expose the PRIMERGY BX600 S2 basic unit to extreme environ- mental conditions (see from dust, moisture, and heat. Installation Steps The installation steps are described in detail in the following sections of this...
  • Page 34: Unpacking The Basic Unit

    CAUTION! Please note the safety instructions in the page Do not unpack the PRIMERGY BX600 S2 basic unit until you have finished transporting it. We recommend that you do not throw away the original packaging material! It may be required for future transportation.
  • Page 35: Installing The System In The Rack

    Installing the System in the Rack CAUTION! For safety reasons, at least two people are required to install the PRIMERGY BX600 S2 basic unit because of its weight and size. Please observe the safety precautions and references to rack instal- lation in the chapter “Important Notes”...
  • Page 36 The rails have with a linear alignment option to also allow adjustment to different rack depths. – No support for the cable management delivered with the mounting kit. This cable management is customized for the Fujitsu Siemens Computers PRIMECENTER rack. – Climatic conditions.
  • Page 37 (air flow from the front to the rear). – Power supply. For installation in 3rd-party racks, you must ensure that appropriate socket strips are present. Figure 5: Mechanical conditions PRIMERGY BX600 S2 Basic Unit Installing the System in the Rack...
  • Page 38: Mounting The Assembly Kit

    (see also “Related Publications” on page To mount the PRIMERGY BX600 S2 basic unit in the rack, you must first mount two support brackets on the rear left support upright of the rack. The first one must be mounted level with the lower edge of the device, while the second must be mounted level with the upper edge of the first.
  • Page 39 Ê Fasten the six screws for adjusting the rail length (1). Ê Repeat the procedure for the second rail. Note that for this rail no support bracket is necessary. PRIMERGY BX600 S2 Basic Unit Installing the System in the Rack figure 6 on page...
  • Page 40: Mounting/Removing The Basic Unit

    Mounting/Removing the Basic Unit CAUTION! For safety reasons, at least two people are required to mount or remove the PRIMERGY BX600 S2 basic unit because of its weight and size. Please note the relevant safety instructions in in the Rack” on page Before lifting the basic unit into the rack, remove server blades, fan units and power supplies from the basic unit to reduce weight.
  • Page 41: Connecting External Devices

    Ê Pull out the basic unit and carefully remove it from the rack. Connecting External Devices The external connectors of the PRIMERGY BX600 S2 basic unit are located on the rear of the basic unit. The external connectors of the server blades are located on the front of the basic unit.
  • Page 42 2, 8 Slots for various types I/O blades, connected to the optional I/O modules of the server blades. These I/O blades can be Ethernet or Fibre Channel switch blades or pass-thru blades, see Thru Blade” on page Channel Pass-Thru Blade” on page Serial port connector on management blade 2 (see also Standard serial port, management communication port.
  • Page 43: Cable Routing

    PCI Cards with Cable at the Front If a PCI expansion module is installed in a server blade, you will have to connect the PCI port with an external device on the back of the rack. To route the cable...
  • Page 44 5 and 6 of the basic unit. This is why about 100 mm of space is required in front of the server due to the bend radius of the SCSI cable. The curved design of the PRIMECENTER rack door ensures that there is sufficient room for slots 5 and 6.
  • Page 45: Instructions On Connecting And Disconnecting Cables

    Ê Unplug all data communication cables from the utility sockets. Ê Undo the nut retention on the connector housings and pull the corre- sponding cables out of the basic unit and the peripherals. PRIMERGY BX600 S2 Basic Unit Connecting External Devices...
  • Page 46: Connecting The System To The Mains

    (1), and then plug the power plug (2) into the USV, Power Distribution Unit (PDU) or into an external socket. CAUTION! Always connect the power cable to the power supply units first, and then to the mains. chapter “Power Supply 139). PRIMERGY BX600 S2 Basic Unit Installing the Hardware...
  • Page 47 Phase redundancy is possible in regions, where a single phase provides 200 - 240V; in other regions with lower single phase voltage, two phases must be coupled and complete phase redundancy thus is not possible. PRIMERGY BX600 S2 Basic Unit Connecting the System to the Mains 165).
  • Page 49: Preparation For Use And Operation

    All unoccupied component slots are fitted with corresponding dummy modules to ensure that the electromagnetic emission properties of the system are observed and that the system components are cooled properly. Figure 14: PRIMERGY BX600 S2 basic unit PRIMERGY BX600 S2 Basic Unit chapter “Important Notes”...
  • Page 50: Operating And Indicator Elements Of The Basic Unit

    When the basic unit is switched ON, pressing the power button for 10 seconds will switch it OFF. Preparation for Use and Operation 1 2 3 4 PRIMERGY BX600 S2 Basic Unit...
  • Page 51 SUM error: A malfunction has occurred in the system. Front identify button Pressing this button lights up the integrated front identify indicator. The front and rear identify indicators will be synchronized. PRIMERGY BX600 S2 Basic Unit Operating and Indicator Elements...
  • Page 52: The Rear

    Figure shows the operator panel of the standard KVM blade. For further information on this KVM blade and on the adv. KVM blade, see Preparation for Use and Operation chapter “KVM Blade” on page PRIMERGY BX600 S2 Basic Unit 133.
  • Page 53: Switching The Basic Unit On/Off

    Preparation for Use and Operation Switching the Basic Unit ON/OFF CAUTION! Make sure that the PRIMERGY BX600 S2 basic unit is connected to the mains for at least one minute before pressing the power ON/OFF button to switch the system ON.
  • Page 54 The basic unit must be powered ON. The server blade can be switched ON and OFF in the following ways: – To switch ON the server blade, press the power button of the server blade (see the manual for the relevant server blade type).
  • Page 55: Management Blade Configuration

    Preparation for Use and Operation Management Blade Configuration The two redundant management blades provide functionality for remote control of the PRIMERGY BX600 S2 base unit over the LAN (see “Management Blade” on page 125 Systems: RemoteView Management Blade - User Interface manual).
  • Page 56 19 on page When you have logged on, the main menu of the console menu will be displayed. Figure 18: Console menu Preparation for Use and Operation figure 17 below). 57). PRIMERGY BX600 S2 Basic Unit page 56). Failure...
  • Page 57 The Management Agent menu looks like this: Figure 19: Management Agent menu. Ê Enter 1 to call up the Management Agent Information menu. The Management Agent Information menu provides access to the parameters required by the LAN connection. PRIMERGY BX600 S2 Basic Unit Management Blade Configuration...
  • Page 58 Ê Select 2 to enter the network mask of your subnet. Ê Select 3 to enter the IP address of your gateway. Ê Select 18 to call up the Agent NTC Duplex Mode menu. Preparation for Use and Operation PRIMERGY BX600 S2 Basic Unit...
  • Page 59 BX Blade Server Systems: RemoteView Management Blade - User Interface Description”. Information on the configuration of the various switch blade models can be found in sparate manuals, see page 165. PRIMERGY BX600 S2 Basic Unit Management Blade Configuration below). “Related Publications” on “PRIMERGY...
  • Page 60: Updating System Components

    Updating BX600 System Components Updating System Components All files required for updating the PRIMERGY BX600 S2 basic unit components are available from http://www.fujitsu-siemens.com/support/downloads.html. 5.4.1 Updating the Server Blade Firmware (BIOS and BMC) You can update both the firmware of the server blade BIOS and the firmware of the server blade BMC.
  • Page 61 Figure 22: Updating the server blade BIOS via the web interface Ê In the TFTP Server IP Address field, enter the IP address of the TFTP server which provides the BIOS image file for the server blade firmware.
  • Page 62: Updating The Management Blade Firmware

    Ê Check the LAN connection by pinging the relevant management blade. Ê Enter the IP address of the TFTP server which provides the BMC image file for the management blade firmware. Enter the path and the file name of the image file for the management blade.
  • Page 63 Figure 24: Updating the management blade firmware via the web interface Ê Make sure that both management blades are connected to the LAN. Ê Enter the IP address of the TFTP server on which the image file for the management blade firmware is provided.
  • Page 64: Updating The Switch Blade Firmware

     Enter selection or type (0) to quit: 2 Ê In the Console Redirection Table menu, select the menu item Console Redirect Switch Blade. Preparation for Use and Operation Console Menu page_root page_0. PRIMERGY BX600 S2 Basic Unit      ...
  • Page 65 Ê Check the newly created LAN connection by pinging the switch blade on the client system. Ê Install your TFTP server software and start it. Ê Download the TFTP update package BX600 S2_TFTP- IMAGES_<version>.exe from the Fujitsu Siemens download server at http://www.fujitsu-siemens.com/support/downloads.html. PRIMERGY BX600 S2 Basic Unit Updating BX600 System Components page_3_2.
  • Page 66 For information on the image file names, see the readme file of the update package. Ê Start an Internet browser on the client server. Enter the IP address specified above in the address field. Enter the user name and password admin. The home page is displayed.
  • Page 67 After resetting, the switch blade will reboot. However, all settings specified previously (IP address etc.) will be lost and must be reentered on the management console. Ê Repeat the firmware update procedure for each installed switch blade. PRIMERGY BX600 S2 Basic Unit Updating BX600 System Components...
  • Page 69: Property And Data Protection

    This protection mechanism can be activated by setting a user password in the Security menu. Preventing Unauthorized Boot Process This protection mechanism can be activated by setting a password on boot in the Security menu. PRIMERGY BX600 S2 Basic Unit 165).
  • Page 71: Server Blades

    Server Blades This chapter describes how to install and uninstall server blades and server blade dummy modules in the PRIMERGY BX600 S2 basic unit, and what you need to be aware of when doing this. The information necessary for installing and operating the various server blade models can be found in separate manuals (see “Related Publications”...
  • Page 72 Server Blades The 4-way server blade is twice the height and occupies two slots (figure 29). Figure 29: PRIMERGY BX630 scalable server blade (4-way configuration PRIMERGY BX600 S2 Basic Unit...
  • Page 73: Installation Sequence

    Server Blades Installation Sequence On the front of the PRIMERGY BX600 S2 basic unit are ten slots for server blades (numbered 1 - 10 from left to right). Figure 30: BX600 S2 basic unit with ten 2-way server blades All ten slots are connected to the infrastructure modules on the back of the BX600 S2 basic unit via the midplane of the BX600 S2 basic unit: –...
  • Page 74 Installation Sequence The order in which the server blade slots are filled depends on whether you are using 2-way server blades or 4-way server blades or a mix of the two, and how the server blades are equipped. Configuration Diagram for 2-way Server Blades –...
  • Page 75 2-way server blades with SCSI controller can only be fitted in slots 5 and 6. If only one 2-way server blade with SCSI controller is to be fitted, it must go in slot 5, with a dummy server blade in slot 6.
  • Page 76: Adding A Server Blade To The Basic Unit

    Configuration Diagram for a Mix of an 8-way Server Blade with 4-way and 2-way Server Blades Begin with the 8-way server blade in slots 1-4, followed by the 4-way Server- Blades and the 2-way Server-Blades. Server blades with SCSI controller can only be fitted in slots 5 and 6.
  • Page 77 Server Blades If you want to add a server blade, you must first remove the dummy module from the corresponding slot. Figure 35: Removing a server blade dummy module Ê Release the locking mechanism of the ejecting handles by pressing the touch points on the inside of both handles (1) simultaneously.
  • Page 78 Devices” on page Figure 36: Turning the eject handles into the unlocked position (2-way server blade) Ê Press the touch points on the inside of the eject handles (1) of the server blade to disengage the locking mechanism of the handles.
  • Page 79 Server Blades Figure 38: Inserting the server blade Ê Push the server blade into the slot as far as possible while keeping the eject handles in the unlocked position. Please make sure you install the server blade in the right direction.
  • Page 80 Devices” on page When you remove the server blade and do not replace it with a new one, you must insert a dummy module in the empty slot. Make sure that the dummy module engages in the slot correctly.
  • Page 81: Lan Switch Blades

    Ethernet LAN Switch Blades This chapter outlines the main features of the switch blades available with the PRIMERGY BX600 S2 blade server. For each switch blade it describes the indicator and connection elements of the control and connection panel. This chapter also describes the port assignment to the server blades and how to install and uninstall the switch blades in the basic unit.
  • Page 82: Gbit Ethernet Lan Switch Blade (Sb9) 6X1Gbit

    LAN link indicator (yellow LED) Glows yellow: Blinks yellow: Dark: Ethernet Switch Blades Port link at 1 Gbit/s Port link at 100 Mbit/s Port link at 10 Mbit/s Network link Network activity No network link or port disabled PRIMERGY BX600 S2 Basic Unit...
  • Page 83 The information necessary for configuring and operating the Gbit Ethernet LAN switch blade (SB9) 6x1Gbit can be found in the manual „PRIMERGY BX Blade Server Systems: LAN Router and Switch Blade - User Interface Description“, “Related Publications” on page PRIMERGY BX600 S2 Basic Unit...
  • Page 84: Gbit Ethernet Lan Switch Blade (Sb9) 6X1 Gbit + 2X10 Gbit

    10 Gbit XFP connector 10 Gbit CX4 connector Port link at 1 Gbit/s Port link at 100 Mbit/s Port link at 10 Mbit/s Network link Network activity No network link or port disabled PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades...
  • Page 85 The information necessary for configuring and operating the Gbit Ethernet LAN switch blade (SB9) 6x1 Gbit + 2x10 Gbit can be found in the manual „PRIMERGY BX Blade Server Systems: LAN Router and Switch Blade - User Interface Description“, see...
  • Page 86: Cisco Catalyst Blade Switch 3040

    Glows green or Cisco IOS is operating normally. amber System status/ID indicator (green LED) Glows green: ID- The switch has been selected for identification by the management blade. PRIMERGY BX600 S2 Basic Unit Ethernet Switch Blades...
  • Page 87 Glows green or Link fault. amber The information necessary for configuring and operating the Cisco Catalyst Blade Switch 3040 can be found in the manual „PRIMERGY BX Blade Server Systems: Cisco Catalyst Blade Switch 3040“, see page 165). PRIMERGY BX600 S2 Basic Unit Cisco Catalyst Blade Switch 3040 “Related Publications”...
  • Page 88: Gbit Switch Blade 10/2

    10 Gbit Switch Blade 10/2 10 Gbit Switch Blade 10/2 The 10 Gbit switch blade 10/2 is designed to transport all blade server I/O, including network and storage, between the server blades and their associated I/O devices. The 10 Gbit switch blade 10/2 provides the following features: –...
  • Page 89 Power indicator (amber LED) Dark: Power enabled Glows: Power disabled ID indicator (green LED) Glows: Switch blade is operating Blinks: The switch blade has been selected for identification by the management blade. PRIMERGY BX600 S2 Basic Unit 10 Gbit Switch Blade 10/2...
  • Page 90: Port Assignment Of The Lan Switch Blades

    Port Assignment of the LAN Switch Blades Port Assignment of the LAN Switch Blades For each of the ten server blade slots, connections are available to the two ports of the onboard LAN controllers and to the two ports of the optional gigabit Ethernet daughter card.
  • Page 91 NET3 and NET4 takes place accordingly. Configuration with Ten 2-way Server Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with ten 2-way server blades. Switch blade 1 Switch blade 2...
  • Page 92 Configuration with Five 4-way Server-Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with five 4-way server blades. Switch blade 1 A B A B A B A B A B A B A B A B A B A B...
  • Page 93: Installing A Lan Switch Blade

    Configuration with a Combination of 2-way and 4-way Server Blades The following figure illustrates the assignment of the switch blades to the LAN ports of the server blades in a configuration with two 4-way server blades and six 2-way server blades.
  • Page 94 Ê Press the spring (1) on the underside of the handle (a) to unlock it. Ê Swing the handle (a) in the direction of the arrow (2) until the locking mechanism of the dummy module disengages. PRIMERGY BX600 S2 Basic Unit...
  • Page 95 Read the safety information and the information on handling electro- static-sensitive components in the static-Sensitive Devices” on page Ê Remove the LAN switch blade from its package. PRIMERGY BX600 S2 Basic Unit Installing a LAN Switch Blade “Inserting the LAN section “Components With Electro-...
  • Page 96 Ê Push (1) the LAN switch blade as far as possible into the desired slot (here slot 2). Ê Swing up (2) the eject handle (a) of the switch blade until the locking mechanism of the LAN switch blade engages. Ethernet Switch Blades PRIMERGY BX600 S2 Basic Unit...
  • Page 97 EMC regulations (regulations on electromagnetic compatibility) and for fire protection. Make sure that the dummy module engages in the slot correctly. PRIMERGY BX600 S2 Basic Unit Installing a LAN Switch Blade 94). section “Components With Electro-...
  • Page 99: Ethernet Pass-Thru Blade

    The Ethernet LAN Pass-Thru-Blade provides ten RJ45 ports for direct (“pass- thru”) connections to the server blades. Figure 52: Ethernet LAN Pass-Thru-Blade The PRIMERGY BX600 S2 basic unit offers slots for up to four Ethernet LAN Pass-Thru-Blades on the back, see figure 54 on page 101.
  • Page 100: Control And Connection Panel

    Figure 53: Control and connection panel of the Ethernet LAN Pass-Thru-Blade The following display and control elements are available: 1 ... 10 RJ45 connectors The RJ45 connectors are assigned to the server blades in accordance with their numbering (for server blade slot numbering see page 73).
  • Page 101: Port Assignment Of The Gigabit Ethernet Pass-Thru Blades

    Ethernet Pass-Thru Blade Port Assignment of the Gigabit Ethernet Pass-Thru Blades The PRIMERGY BX600 S2 basic unit offers four slots for Ethernet LAN Pass- Thru-Blades on the back. The Ethernet LAN Pass-Thru-Blade in slot NET1 is connected to port A of the onboard LAN controller of the installed server blades.
  • Page 102 LAN channels. The Ethernet LAN Pass-Thru-Blades in slots NET1 and NET2 provide connec- tions to channels A and B of the onboard LAN controllers of the server blades. The following figure shows the port assignment in a configuration with ten 2-way server blades.
  • Page 103 LAN channels each. The Ethernet LAN Pass-Thru-Blades in slots NET1 and NET2 provide connec- tions to channels A and B of the onboard LAN controllers of the server blades. The following figure shows the port assignment in a configuration with five 4-way server blades.
  • Page 104: Replacing An Ethernet Pass-Thru Blade

    Server Server blade 1 blade 2 Figure 57: Port assignment to the Gigabit Ethernet I/O modules with five 4-way server blades Replacing an Ethernet Pass-Thru Blade CAUTION! Ethernet pass-thru-blades must always be installed in slots NET1 and NET3 first (see...
  • Page 105: Fibre Channel Switch Blade

    The PRIMERGY BX600 S2 base unit can be fitted with two FC switch blades. The slots for the FC switch blades are on the rear of the base unit (NET3 and...
  • Page 106: Control And Connection Panel

    The LED might also blink while testing. Management blade display (2-color LED) Lights up when the FC switch blade is being controlled directly via the management blade user interface. section “Fibre Channel SFP module” on PRIMERGY BX600 S2 Basic Unit FC Switch Blade...
  • Page 107 FC transfer rate 1Gbit/s Lights green: FC transfer rate 2Gbit/s Lights amber: FC transfer rate 4Gbit/s PRIMERGY BX600 S2 Basic Unit Control and Connection Panel LAN transfer rate 100 Mbit/s LAN connection is available FC port on-line, data transport slow: FC port on-line, but segmented.
  • Page 108: Port Assignment

    Connections to the two fabric ports of the optional fibre channel daughter card are provided for each of the ten server blade slots. In the case of 4-way server blades, connections for a total of four fabric ports are therefore available.
  • Page 109 Configuration with ten 2-way server blades The illustration below shows the assignment of FC switch blades to the fabric ports of the server blades in a configuration with ten 2-way server blades. FC switch blade NET3 A B A B A B A B A B A B A B A B A B A B...
  • Page 110 Server Blade 5 Blade 1 Figure 62: Fabric port assignment with five 4-way server blades When using the 12-port version the fabric ports of server blade 4 (slots 9 and 10) are not available. FC switch blade NET4 Server Server...
  • Page 111: Fc Switch Blade Installation

    Configuration with a combination of 2-way server blades and 4-way server blades The illustration below shows the assignment of FC switch blades to the fabric ports of the server blades in a configuration with two 4-way server blades and six 2-way server blades. FC switch blade NET3...
  • Page 113: Fibre Channel Pass-Thru Blade

    SFP module Figure 64: Fibre Channel pass-thru blade The PRIMERGY BX600 S2 basic unit can be fitted with one or two FC pass-thru blades. The slots for these blades are on the back of the system unit (NET 3 and...
  • Page 114: Control And Connection Panel

    Fibre Channel link indicator (amber LED) Fibre Channel SFP connector Slot for Fibre Channel SFP module (see the server blade slots on the front of the BX600 S2 system (see The following table shows the conditions of the Fibre Channel ports indicated by the LEDs.
  • Page 115: Fibre Channel Sfp Module

    Figure 66: Fibre Channel SFP connector Inserting a Fibre Channel SFP module For each server blade connected via Fibre Channel, SFP modules must be plugged into the appropriate FC pass-thru blade slots. For information on the port assignment see section “Installation Sequence”...
  • Page 116 Figure 68: Removing an SFP module Ê Swivel the locking clip in the direction of the arrow (1) to disengage the locking mechanism of the SFP module and pull it out of the slot (2). FC Pass-Thru Blade PRIMERGY BX600 S2 Basic Unit...
  • Page 117: Port Assignment Of The Fc Pass-Thru Blades

    FC pass-thru blades must always be installed in slot NET3 first. This ensures that port A of the FC daughter cards is connected if redundant fibre channel connections are not used. If Gigabit Ethernet daughter cards are installed in the server blades, LAN switch blades (see page 99) must be installed in slots NET3 and NET4.
  • Page 118 Each FC pass-thru blade has ten front slots for SFP modules, via which the Fibre Channel connections to the server blades are established. The SFP modules are assigned to the server blades according to the numbering of the slots (see...
  • Page 119 The following figure illustrates the assignment of the Fibre Channel ports of the FC pass-thru blades and the server blades in a configuration with ten 2-way server blades when two FC pass-thru blades and, in each server blade, an FC daughter board are installed.
  • Page 120 FC Port Assignment Configuration with Five 4-way Server Blades Because a 4-way server blade occupies two slots in the blade server chassis, there are four connections for four Fibre Channel ports available for a 4-way server blade. To use these connections, two FC daughter boards must be installed on the 4-way server blade (see manual for the relevant server blade type).
  • Page 121: Exchanging An Fc Pass-Thru Blade

    Removing the FC pass-thru blade Figure 74: Disengaging the FC pass-thru blade Ê Press the spring on the underside of the eject handle to unlock it. PRIMERGY BX600 S2 Basic Unit Exchanging an FC Pass-Thru Blade section “Components With 117).
  • Page 122 Ê Remove the FC pass-thru blade from the slot (2). The FC pass-thru blade is inserted using these instructions in reverse order. FC Pass-Thru Blade PRIMERGY BX600 S2 Basic Unit...
  • Page 123 EMC regulations (regulations on electromagnetic compatibility) and for fire protection. Make sure that the dummy module engages in the slot correctly. Figure 76: FC pass-thru blade dummy module PRIMERGY BX600 S2 Basic Unit Exchanging an FC Pass-Thru Blade...
  • Page 125: Management Blade

    Figure 77: Management blade slots Important note: Management blades to be used in the PRIMERGY BX600 S2 base unit must have order number A3C40073243. Compatibility with the S1 model management blade used in the PRIMERGY BX600 base unit is not provided.
  • Page 126: Control And Connection Panel

    LAN connector (with two integrated LAN status LEDs (see next positions 3 and 4)) LAN port, RJ45, 10Mb management LAN. LAN link indicator (green LED) Lights green: The LAN is linked. Blinks green: Boot up power ready indicator. Management Blade PRIMERGY BX600 S2 Basic Unit...
  • Page 127 LAN active indicator (amber LED) Lights amber: The LAN is active. Blinks amber: Boot up power ready indicator. I2C connector Proprietary I2C (IPMI) connector for Fujitsu Siemens Computers service applications. Failure indicator (amber LED) Dark: This management blade is OK (see table below).
  • Page 128: Exchanging The Battery

    Make sure you insert the battery the right way round. The plus pole must be at the top! The following figure shows the position of the battery (1) on the management blade board. Figure 79: Position of the management blade battery (arrow) Management Blade PRIMERGY BX600 S2 Basic Unit...
  • Page 129 (2). Ê Place the new battery of the same type in the holder (3) and push it in the direction of the arrow (4) until it slots into place. PRIMERGY BX600 S2 Basic Unit Exchanging the Battery...
  • Page 130: Exchanging A Management Blade

    Devices” on page Removing the Management Blade Figure 81: Disengaging the management blade Ê Press the spring on the underside of the eject handle to unlock it. Management Blade section “Components With Electro- PRIMERGY BX600 S2 Basic Unit...
  • Page 131 Figure 82: Disengaging the management blade Ê Swing the eject handle of the management blade in the direction of the arrow until the locking mechanism disengages and the blade is ejected a few centi- meters. PRIMERGY BX600 S2 Basic Unit Exchanging a Management Blade...
  • Page 132 Both management blades must always be plugged in to ensure cooling, to comply with the applicable EMC regulations (regulations on electro- magnetic compatibility) and for fire protection. The management blade is inserted by following these instructions in reverse order. Management Blade PRIMERGY BX600 S2 Basic Unit...
  • Page 133: Kvm Blade

    KVM Blade For administering the server blades, the PRIMERGY BX600 S2 basic unit offers a KVM blade, which allows the individual server blades to be connected to a console. Figure 84: Position of the KVM blade The following models are available: –...
  • Page 134 When you press the ID button, the ID LEDs on the control panel on the front of the server blade and on the KVM blade are switched on or off. The ID LEDs on the KVM blade and on the control panel of the blade server are synchronized.
  • Page 135: Adv. Kvm Blade

    KVM blade see the manual Server Systems: RemoteView Management Blade - User Interface Description". Control Panel of the Adv. KVM Blade Figure 86: Adv. KVM blade PRIMERGY BX600 S2 Basic Unit "PRIMERGY BX Blade Adv. KVM Blade...
  • Page 136 LAN port, RJ45, 10/100 Mbit/s. LAN activity indicator (green LED) Dark: LAN connection not active. Blinks green: Active LAN connection. LAN connection indicator (orange LED) Dark: No connection. Glows: LAN connection available. figure 10 on page 43). PRIMERGY BX600 S2 Basic Unit KVM Blade...
  • Page 137: Digital Kvm Blade

    – Password-protected user authentication You can also connect cables from the BX600 digital KVM switch to a KVM appliance such as the Fujitsu Siemens s3-1621 Console Switch. This capability allows you to create large combinations of servers and switches that you can manage from a common access point or over your IP network.
  • Page 138 10 on page console switch. ID indicator Glows: The system has been selected for identification by pressing the front or rear ID button. Blinks: System failure 43) or for the connection to an external PRIMERGY BX600 S2 Basic Unit KVM Blade...
  • Page 139: Power Supply Concept

    Power Supply Concept In the basic configuration, the PRIMERGY BX600 S2 base unit contains two hot swap power supply units (PSU1 and PSU2 in adapt automatically to any voltage within the range 200 V - 240 V. PSU4 PSU2 Figure 88: PRIMERGY BX600 S2 basic unit: power supply units...
  • Page 140: Power Supply Units

    Each power supply unit has a large fan on the front (A) and two smaller fans on the rear (B) that provide air cooling for the system (see front Figure 89: PSU: Fans Power Supply Concept figure 89 below). rear PRIMERGY BX600 S2 Basic Unit...
  • Page 141 On/off display (green LED) Lights up when the PRIMERGY BX600 S2 base unit is switched on. Fault display (amber LED) Lights up if a fault occurs on the power supply unit or if a fan Mains power supply display (green LED) Lights up when the mains connection is re-established.
  • Page 142: 14.1.1 Replacing A Power Supply Unit

    Ê First disconnect the power supply cable of the defective PSU from the mains. Ê Remove the power supply cable from the insulated socket of the defective PSU. CAUTION! Be careful! The PSU can be very hot! Power Supply Concept PRIMERGY BX600 S2 Basic Unit...
  • Page 143 Power Supply Concept Power Supply Units Figure 91: Disengaging the power supply unit (a = green touch point) Ê Press the locking button (a) to disengage the locking mechanism of the PSU handle. PRIMERGY BX600 S2 Basic Unit...
  • Page 144 Power Supply Units Power Supply Concept Figure 92: Removing the power supply unit Ê Swivel the handle completely in the direction of the arrow to unlock the PSU from the chassis PRIMERGY BX600 S2 Basic Unit...
  • Page 145: 14.1.2 Adding A Power Supply Unit

    14.1.2 Adding a Power Supply Unit Depending on the desired configuration, the system can be upgraded with one or two additional power supply units. CAUTION! Read the safety information in the PRIMERGY BX600 S2 Basic Unit Power Supply Units chapter “Important Notes” on page...
  • Page 146 ON. Exceeding the five-minute limit may damage components. All unoccupied PSU slots in the blade server system are fitted with PSU dummy modules (figure 94) to ensure that the electromagnetic emission properties of the system are observed and that the system components are properly cooled.
  • Page 147 Ê Insert the additional power supply unit in the corresponding slot and connect it to the mains. PRIMERGY BX600 S2 Basic Unit Power Supply Units...
  • Page 149: Ventilation Concept

    The fan units are accessible from the rear of the system and contain two fans each. Figure 95: PRIMERGY BX600 S2 basic unit: fan units When a fan in a fan or power supply unit/PSU dummy module fails, the amber...
  • Page 150: The Fan Unit

    The LEDs can be activated via a pushbutton (b) after the fan unit has been removed from the chassis. (figure 96) on the front of the fan unit for fan status Fan 1 LEDs (amber) Ventilation Concept Fan 2 LEDs (green) (amber) PRIMERGY BX600 S2 Basic Unit...
  • Page 151: 15.1.1 Replacing The Fan Unit

    The defective fan must be replaced within a reasonable amount of time (max. 2 minutes). Figure 97: Disengaging the fan unit (a = green touch point) Ê Press the locking button (green) to disengage the locking mechanism of the unit handle. PRIMERGY BX600 S2 Basic Unit The Fan Unit...
  • Page 152 Figure 98: Removing the fan unit Ê Swivel the handle completely down to disengage the locking mechanism and pull out the rear fan unit. To mount a fan unit, follow these instructions in the reverse order. PRIMERGY BX600 S2 Basic Unit...
  • Page 153: 15.1.2 Replacing A Fan In The Unit

    Figure 99: Disengaging the fan unit (a = green touch point) Ê Pull (1) the locking handle (green) to disengage the fan. Ê Remove the fan from the unit (2). To mount a fan, follow these instructions in the reverse order. PRIMERGY BX600 S2 Basic Unit...
  • Page 155: Troubleshooting And Tips

    Ê Unplug the power cables from the insulated sockets of the power supply units. Ê Wait a few seconds and plug the power plugs into the insulated sockets again. Ê Switch ON your system. PRIMERGY BX600 S2 Basic Unit chapter “Important Notes” on 50) remains unlit after you have 46). section...
  • Page 156: Front Or Rear Identify/Fault Led Blinks Amber

    Ê If the switch blade is still indicated as defective, exchange it (see “Installing a LAN Switch Blade” on page 50) one of the malfunctions 141): 153). 93). PRIMERGY BX600 S2 Basic Unit Troubleshooting and Tips section “Operating figure “Power 142). section “Replacing...
  • Page 157: System Switches Itself Off

    Ê Check whether the data cable is properly connected to the system and monitor (if it is plugged in with a connector). Ê Switch on the monitor. PRIMERGY BX600 S2 Basic Unit System Switches Itself OFF “PRIMERGY BX Blade...
  • Page 158: Flickering Stripes On The Monitor Screen

    Ê Check whether the mouse driver is properly installed and activated. Infor- mation on the mouse driver can be found in the documentation for the mouse, the operating system or the application program. Troubleshooting and Tips PRIMERGY BX600 S2 Basic Unit...
  • Page 159: Floppy Disk Cannot Be Read/Written

    Ê Set the time and/or date in the operating system or in the BIOS Setup for the corresponding server blade. If the time and date are repeatedly wrong when you switch on your server blade, you must change the lithium battery (see the manual for the relevant server blade type).
  • Page 160 (on the ServerBooks CD under the heading “Controllers”). Ê Remove the drive and reinstall it with the system switched on. If the drive is still identified as defective, you will need to replace it. Troubleshooting and Tips PRIMERGY BX600 S2 Basic Unit...
  • Page 161: Abbreviations

    Advanced Technology Attachment BIOS Basic Input-Output System Compact Disk Communication Central Processing Unit DBMS Database Management System Double Data Rate (RAM) DIMM Dual Inline Memory Module Digital Video Disk Error Correcting Code Error Detection Code Electromagnetic Compatibility PRIMERGY BX600 S2 Basic Unit...
  • Page 162 Abbreviations Electrostatic Discharge Fibre Channel Global Array Manager Hard Disk Drive Height Unit Input/Output Identification Integrated Drive Electronics Internet Protocol Local Area Network Liquid Crystal Display Light-Emitting Diode Manually Retention Latch Network Interface Card PRIMERGY BX600 S2 Basic Unit...
  • Page 163 Power Supply Unit RAID Redundant Arrays of Independent Disks Read-Only Memory Storage Area Network Serial Attached SCSI SATA Serial ATA Single Connector Attachment SCSI Small Computer System Interface Server Configuration Utility Small Form Factor Pluggable PRIMERGY BX600 S2 Basic Unit Abbreviations...
  • Page 164 Abbreviations Universal Serial Bus Video Graphics Adapter Vital Product Data Wakeup on LAN PRIMERGY BX600 S2 Basic Unit...
  • Page 165: Related Publications

    The PDF files for the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found at: http://manuals.fujitsu-siemens.com (select: industry standard servers). Safety...
  • Page 166 PRIMERGY BX Blade Server Systems: Cisco Catalyst Blade Switch 3040 Software Configuration Guide [21] PRIMERGY BX Blade Server Systems: Cisco Catalyst Blade Switch 3040 System Message Guide [22] BX600 Digital KVM Switch Quick Installation Guide PRIMERGY BX600 S2 Basic Unit...
  • Page 167 [23] BX600 Digital KVM Switch User Guide [24] BIOS-Setup Beschreibung/Reference Manual PRIMERGY BX600 S2 Basic Unit Related publications...
  • Page 169: Index

    CE label 15, Class A Compliance Statement component hot-swappable components hardware/software configuring server connecting cables PRIMERGY BX600 S2 Basic Unit external devices consumables Control panel Ethernet pass-thru-blade FC switch blade LAN switch blade Management blade data manipulation data protection date...
  • Page 170 SFP module Switch blade flash EPROM floppy disk cannot be read/written height units hot-swap fan module management blade power supply unit server blade switch blade indicators power supply unit system information additional installation steps overview PRIMERGY BX600 S2 Basic Unit...
  • Page 171 Battery Control panel exchanging meaning of the symbols model rating plate mouse no mouse pointer on screen Netzteil 11, PRIMERGY BX600 S2 Basic Unit noise level notational conventions notes on safety operating elements system overloading overview BX600 basic unit installation...
  • Page 172 ON unpacking ventilation system power LED remains unlit target group technical data time incorrect transport damage unpacking system user password ventilation fan in power supply unit 12, fan module 12, system ventilation clearance weight PRIMERGY BX600 S2 Basic Unit...
  • Page 173 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents