SCSI hard disk subsystem
V
CAUTION!
Keep the dummy cover/module for future use. If the hard disk drive is
removed again and not replaced with a new drive, then the dummy
cover/module must be reinstalled to satisfy cooling requirements, the
applicable EMC regulations (regulations on electromagnetic compati-
bility), and fire protection measures.
Installing is done in the reverse order.
If a hard disk drive has been removed and no new drive is installed in its place,
then install a dummy cover in the empty bay. Make sure that the dummy
cover/module engages properly in the bay.
Installing 1.6-inch hard disk drive
Figure 22: Installing the 1.6-inch hard disk drive
Ê Push the hard disk drive module into the bay (1) as far as possible, and then
swing the handle of the hard disk drive module completely down to allow the
locking mechanism to engage (2).