Parameterization Using The Bop20; General Information About The Bop20 - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

A.4

Parameterization using the BOP20

A.4.1

General information about the BOP20

The BOP20 (Basic Operator Panel 20) can be used to switch on and switch off drives during
the commissioning phase as well as to display and modify parameters. Faults can be
diagnosed as well as acknowledged.
The BOP20 is snapped onto the Control Unit. To do this, the blanking cover must be
removed (for additional information on mounting, please refer to the SINAMICS S120
Manual Control Units and Supplementary System Components).
Displays and keys
Figure A-8
Information on the displays
Table A- 1
LED
Display
top left
2 positions
RUN
top right
2 positions
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Overview of displays and keys
Meaning
The active drive object of the BOP is displayed here.
The displays and key operations always refer to this drive object.
Lit if at least one drive in the drive line-up is in the RUN state (in operation).
RUN is also displayed via bit r0899.2 of the drive.
The following is displayed in this field:
More than 6 digits: Characters that are still present but are invisible
(e.g. "r2" ––> 2 characters to the right are invisible, "L1" ––> 1 character to the left is invisible)
Faults: Selects/displays other drives with faults
Designation of BICO inputs (bi, ci)
Designation of BICO outputs (bo, co)
Source object of a BICO interconnection to a drive object different than the active one.
A.4 Parameterization using the BOP20
Appendix
1053

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents