Siemens SINAMICS S120 Function Manual page 855

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

I&M parameters
Table 11- 18 Parameter designation, assignment and meaning
I&M parameter
Format
designation
I&M 0:
-
IM_SUPPORTED
I&M 1:
Visible
TAG_FUNCTION
string
I&M 1:
Visible
TAG_LOCATION
string
I&M 2:
Visible
INSTALLATION_D
string
ATE
I&M 3:
Visible
DESCRIPTOR
string
I&M 4:
Octet
SIGNATURE
string
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Size/oct
Initialization
ets
-
-
32
Space
0x20...0x20
22
Space
0x20...0x20
16
Space
0x20...0x7E
54
Space
0x20...0x20
54
Space
0x00...0x00
11.3 Communication via PROFINET IO
SINAMICS
Meaning
parameters
r8820[62,63]
The parameter indicates which I&M data sets
are supported.
The value 0x1E indicates that I&M data sets
1...4 are available.
p8806[0...31]
Text that identifies the function or task of the
device.
p8806[32...53]
Text that identifies the device location.
p8807[0...15]
Text with the date of the installation or the
initial commissioning of the device. The fol-
lowing date formats are supported:
YYYY-MM-DD
YYYY-MM-DD hh:mm
YYYY: Year
MM: Month 01...12
DD: Day 01...31
hh: Hours 00...23
mm: Minutes 00...59
The separators between the individual speci-
fications, i.e. hyphen '-', blank ' ' and colon ':',
must be entered.
p8808[0...53]
Text with any comments or notes.
r8809[0...53]
The parameter is automatically populated by
the system, in which case it contains a func-
tional check signature for the change tracking
with Safety Integrated. The check signature
has the following format:
The first four octets (0...3) contain the
content of parameter r9781 index 0: "SI
change monitoring checksum (Control
Unit)".
The second four octets (4...7) contain the
content of parameter r9782 index 0: "SI
change monitoring time stamp (Control
Unit)".
The remainder (octets 8...53) contains
zeroes.
Communication
855