Annex
Tab. 119 Electrical data
Class of protection
Input voltage
Input current
Resistant to voltage breaks
Power input with min. configuration
Power input with max. configuration
Undervoltage limit
(system reset, data backup)
Tab. 120 Heat dissipation
Basic system with auxiliary power supply unit
Maximally configured system
7. 3. 4

Dimensions of cards and modules

Tab. 121 Dimensions of cards and fan-out panels
Card
Interface cards
Call Manager card CPU1
Applications card CPU2
Fan-out panel FOP
Tab. 122 Modules
Card
DSP module
IP Media module
Charge module
264
Internal power supply Aastra
470
1
103 V...127 V or 207 V...253 V,
48...62 Hz
approx. 0.2 A...2.2 A (with 115 V)
approx. 0.1 A...1.1 A (with 230 V)
< 20ms
approx. 25 W
approx. 140 W
< 90 V
Aastra 470
approx. 140 W = 504 kJ/h
approx. 400 W = 1440 kJ/h
Dimensions width x height x depth [mm]
93 x 41 x 265
154 x 41 x 265
154 x 41 x 265
481 x 44 x 69
Dimensions length x width [mm]
90 x 56
85 x 85
83 x 60
Auxiliary power supply unit
(APS2)
1
100 V...240 V, 48...62 Hz
approx. 0.2 A...4.0 A (with
115 V)
approx. 0.2 A...2.0 A (with
230 V)
< 20ms
approx. 25 W
approx. 260 W
< 90 V
Aastra 470 as of R3.2