Changing The Ip Media Module - Mitel Aastra 470 System Manual

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

Operation and Maintenance
3. Remove the old or defective module by loosening the fastening screw and care-
fully pulling the module out vertically of the module slot.
Note:
If multiple modules are equipped and the defective card is not top-
most, the spacing sleeves have to be loosened and the modules
pulled. The order of the modules on the slot is relevant only if different
types of modules are equipped.
4. Press the new module downward evenly on both connectors to the stop.
5. Secure the module with the fastening screw.
6. Carefully push back the call manager card into the shaft and gently press the
card as far as it goes into the connection on the backplane.
7. Secure the Call Manager card back into its slot with the screw.
8. Restart the call manager by pressing the On/Off button on the call manager
card.
6. 3. 4. 2

Changing the IP media module

IP Media modules are fitted either to the call manager card or to PRI trunk cards.
To replace a defective IP media module to a call manager card, proceed as follows:
Warning
Be sure to observe the
1. Carry out preparations (see
2. Unscrew the screw on the Call Manager card and remove the card by pulling the
fastening screw.
3. Remove the defective module by loosening the 2 fastening screws and carefully
pulling the module out vertically of the module slot.
4. Place the new module in the slot and press it down evenly into the slot as far as
the stop.
5. Fit the module on to the call manager card from below using the 2 fastening
screws.
6. Carefully push back the call manager card into the shaft and gently press the
card as far as it goes into the connection on the backplane.
212
"Safety regulations", page
"Preparations", page
92.
207).
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014