Mitel Aastra 470 System Manual page 240

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

Operation and Maintenance
Event / error message
Synchronisation with backup
communication server failed
Synchronisation with backup
communication server suc-
cessful
Synchronization on trunk re-
established
System memory usage below
the critical range again
System memory usage over
the critical range
System overload
System phone in service again
System phone out of service
Tax counter overflow
Temperature within normal
range again
Temporary activation period
expires on
Terminal power
supply: Overload
240
Trigger condition
The primary communication server was unable
to transmit the configuration data to the
backup communication server.
Note:
This event message is generated by the primary
communication server.
The primary communication server was able
(following one or more previous failed
attempts) to transmit the configuration data to
the backup communication server.
Note:
This event message is generated by the primary
communication server.
A BRI/PRI interface entered in the clock pool has
been successfully re-synchronized with the sys-
tem clock.
Memory usage in the file system for a particular
purpose is again under the critical value
Purpose (file type ID):
0: File system, 1: Application, 2: Crash-Log,
3: Monitor-Log, 4: Announcement service,
5: Voice mail, 6: Music on hold, 7: Backup,
8: Hospitality/Accommodation, 9: User folder
Memory usage in the file system for a particular
purpose has exceeded a critical value
Purpose (file type ID):
0: File system, 1: Application, 2: Crash-Log,
3: Monitor-Log, 4: Announcement service,
5: Voice mail, 6: Music on hold, 7: Backup,
8: Hospitality/Accommodation, 9: User folder
Network access attempted when all lines are
seized or the system is overloaded.
A system phone on the DSI bus is ready for
operation again.
A system phone on the DSI bus is defective or
was disconnected.
Individual cumulative counter or cost centre
counter overflow
Following overheating, the temperature inside
the communication server is back in the normal
operating range.
Reminder of the missing, definitive activation
licence following connection set-up with the
communication server.
Rated output slightly exceeded for > 4 s (see
also
"Overload shutdown", page
Details
Backup communication server
ID, date, time
Backup communication server
ID, date, time
Port number, date, time
File type ID, memory usage in
%, date, time
File type ID, memory usage in
%, date, time
Route number, user number,
date, time
Card number, port number,
user number, date, time
Card number, port number,
user number, date, time
Cause (0: User / 1: Cost centre /
2: Exchange line / 3: Room),
number, date, time
Card number, temperature,
date, time
Expiration date [DD.MM.YYYY],
date, time
Date, time
88).