Installation
Tab. 74
LED on the EFOP fan-out-panel
8 LEDs (2 x LED 1...4)
All LEDs lit
Individual LEDs off
All LEDs off
Notes:
– The EFOP fan-out-panel is reset from emergency operation to normal
operation with a delay of 3 minutes. This allows the communication
server to reboot after a power failure. The delay also applies to individ-
ual FXS lines.
– If individual FXS lines are in emergency operation, the corresponding
analogue exchange line from the communication server can no longer
be used. Unexpected faulty switching may occur if an active call was
being made on the FXS line and the exchange line prior to the emer-
gency operation.
– In emergency operation the emergency phone is connected directly
with the analogue exchange line so no exchange access prefix has to
be dialled.
156
Meaning
Normal operation
There is no power to these FXS lines. Possible
causes:
• Individual ports are switched off due to over-
heating or overloading. the FXS ports are deac-
tivated in groups of 4 ports.
• The FXS card is defective.
• Individual FXS lines to the communication
server are interrupted.
All the FXS lines are without power. Possible
causes:
• The power supply to the communication
server has failed or there is a complete mains
power outage.
• As a result of a defect the communication
server is temporarily or permanently out of ser-
vice.
• All the ports are switched off due to overheat-
ing or overloading.
• One or more FXS cards are defective.
• All the FXS lines to the communication server
are interrupted.
Result
All the emergency phones and
the analogue exchange lines
are connected with the ports of
the communication server.
The emergency phones on
these ports are directly con-
nected with the corresponding
analogue exchange lines.
All the emergency phones are
directly connected with the cor-
responding analogue exchange
lines.
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014