Connection
The EFOP fan-out-panel comprises 5 connection blocks of 10 RJ45 sockets each.
The line switchover is carried out on the two left-hand connection blocks. The
three right-hand connection blocks are used for separating the four-fold assigned
RJ45 sockets FXS1-4 and FXO1-4.
On FXS or FXO interface cards with four-fold assigned RJ45 sockets, direct wiring to
the FXS1-4 and FXO1-4 sockets of the EFOP fan-out-panel is possible. The unas-
signed connection blocks can be used for other purposes.
The diagram below shows the connection between an EFOP fan-out-panel and 8
emergency phones and 8 analogue exchange lines.
3
1
PSTN
1
3
1 PSTN 3
2
4
2 PSTN 4
4
PSTN
2
Fig. 68
Connection of EFOP fan-out-panel (example)
The patch cables are available separately in lengths of 1 and 2 m (see
Overview", page
260).
The internal wiring of the 3 right-hand connection blocks is the same as for the FOP
fan-out-panel (see
Tab.
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014