Mitel Aastra 470 System Manual page 161

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

First-start response
The IP addressing after a first start depends on whether a static IP addressing is al-
ready stored on the EIM card from a previous configuration. A static IP addressing
(IP address, subnet mask, gateway) entered manually is stored on the EIM card and
remains available after a first start. This means that the communication server re-
mains accessible via Ethernet interface in the same way as before the first start.
If no IP addressing is entered on the EIM card (e.g. after initial delivery), the commu-
nication server is started with DHCP after a first start. The communication server
tries to log on with the DHCP server and to enter its host name on the DNS server. If
logon is successful the communication server is accessible via the host name.
If the communication server cannot find a DHCP server within 90 seconds, it deacti-
vates the DHCP mode and is then accessible via the standard IP address (see
Tab.
76) with a direct connection.
Note:
DHCP is deactivated only temporarily and is reactivated after a subse-
quent restart.
Cable types
The Ethernet switch on the communications server features Auto MDI/MDIX. With
the automatic detection straight or crossover LAN cables can be used for all con-
nection types.
Configuration
The Ethernet interfaces routed to the front panel can be configured individually in
the
IP addressing
(
possible for
Speed
and
Status LED
The status of the Ethernet interfaces is indicated by the green and yellow LEDs di-
rectly on the interface in question.
Fig. 71
Status LED on the Ethernet interfaces
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
=9g) view. In addition to Auto modes, manual settings are also
MDI
type.
Installation
161