Connecting
6.2 Electrical connection
6.2.7

Connecting to a converter

To connect the motor to a converter, use MOTION-CONNECT cables or shielded connecting
cables.
The braided shielding must have good electrical conductivity. Prefer braided shielding made
of copper or aluminum.
The shield must be connected at both ends to the motor and the converter; unshielded cable
ends must be kept as short as possible.
Attach the shielding with a large area as 360° contact to the converter and to the motor. Use
for instance, EMC glands at the cable entries.
6.2.8

Connection overview

The circuit diagram contains information about wiring and connecting the motor winding.
1
2
3
4
Figure 6-2
108
Ground connection
Temperature sensor (1 x reserve)
Encoders
VP module (if required)
Circuit diagram with SIMODRIVE (example)
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b