Mechanical mounting
5.5 Mounting the motor spindle
3. Bolt on the bearing shield as specified in Chapter Mounting the stator with cooling jacket
(Page 76). This may necessitate overcoming the radial force F
Figure 5-18
4. Complete the motor spindle in accordance with the project.
5. Fasten the rating plate, supplied as a loose item, securely to the spindle box in a clearly
visible position.
You have mounted the motor spindle.
5.5.4
Mounting the motor spindle with APM rotor
NOTICE
Danger of damage to the rotor banding
The banding (composite composite fiber) must not be damaged and must not come into
contact with the stator bore.
• Remove the protective film only immediately before mounting.
• Use an assembly film.
• Always use a centering assembly fixture for mounting.
88
①
Encoder (separate mounting instructions)
②
Housing bolts
③
Stator core with cooling jacket
④
Rotor core
⑤
Free cable ends
⑥
Flexible tube
Complete_motor_spindle
.
r
⑦
Bearing shield NDE
⑧
Drain hole
⑧
Coolant connection
⑧
Spindle housing
⑧
Spindle shaft with bearings
⑧
Bearing shield DE
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b