Mechanical mounting
5.4 Mounting the stator with the spindle housing
For joining by heating the spindle housing (shrink fit):
● Hot-air oven with temperature monitoring
– Oven volume appropriate for the stator type
– Placement of the oven in the immediate vicinity of the workplace
● Device for cooling the heated-up cooling jacket.
5.4.2

Mounting preparation

Procedure
1. Check that the components are correct and complete.
2. Check the insulation resistance before mounting stators that have been stored for a
longer period. See Chapter "Test the insulation resistance (Page 125)".
3. Clean the surfaces to be joined
1
2
3
4
Figure 5-9
All surfaces must be free from contamination, rust, sharp edges, shrink holes, damage
and machining marks, in particular:
– The ring slots for the O-ring seals
– The cooling thread on the cooling jacket (for the stator with cooling jacket variant)
– The spindle housing
– The cable duct in the spindle housing
– The drain holes
74
Joining surfaces for the stator to be coated with anti-corrosion agent.
Four slots for the O-ring seals for sealing the stator
Center slots for discharge in the drain holes
Cooling thread
Surfaces and slots for the stator with water cooling
.