Convotherm OEB Series Service Handbook page 90

Table of Contents

Advertisement

Service Handbook OEB/OES/OGB/OGS
Instructions – Removing and assembling the unit parts / components:
The following unit parts / components can and should be removed and descaled.
Proceed step-by-step as described in the previous instructions „Descaling the unit parts /
components".
1.
Injection pipe for direct injection
The injection pipe is fastened with a nut SW10 on the backside of the suction
panel. Loosen the nut and remove the injection pipe
After descaling, assemble the injection pipe with the nut SW10 onto the backside
of the suction panel again.
2.
Injection nozzle for direct injection
The injection nozzle (SW 14) is fastened into the unit ceiling with a union nut.
Using a wrench, unscrew the nozzle SW14.
After chemically descaling, rescrew the nozzle with the union nut on again.
3.
Water inlet for direct injection
Unscrew the injection nozzle (SW 14).
Loosen the union nut SW 19 with a wrench  the water inlet pipe can then be
pulled into the electric connection area.
Loosen hose connection on water inlet and remove pipe from hose.
After chemically descaling, assemble the water inlet with the union nut and the
nozzle again in the reverse process.
4.
t-piece for manometer and pressure switch in the water inlet for direct injection
Unscrew manometer and pressure switch from the t-piece
Loosen hose connection above and below the t-piece and remove t-piece
After chemically descaling, using a needle, make sure that the t-piece has a clear
passage.
Assemble the parts in the reverse procedure
5.
Demoisturizing tub
Remove cover of the demoisturizing tub
Unscrew nozzle, descale and ensure it has a clear passage.
Rescrew nozzle on and place cover on the demoisturizing tub.
6.
Water level probe
Remove water level probe
Attention:
Chemically descale only the probe, do not mechanically clean the surfaces
because the water level probe is galvanized and this coating will be scratched
Remove seal, clean and check
Assemble water level probe with cleaned /new seal and electrically connect
7.
Preheating probe B4
Unscrew probe, chemically descale and assemble again.
Notice:
For heavy scale build up and a water hardness > 18°dH (problem water), we recommend
the following:
Check the water tightness of the steam generator pump and the water level probe
during descaling in the unit
Recommend to your customers a partial decalization system (hydrogen ionic
exchanger i.e. from the company Brita).
Cross reference:
Service Handbook 4.3.2 "Half-automatic Oven cleaning"
Service Handbook 4.3.3 "Automatic cleaning system CONVOClean system (Option)"
Installation Handbook Chapter 4.1 "Water inlet"
AS/11-2011
4_04e_CONVOTHERM Descaling_b