Convotherm OEB Series Service Handbook page 189

Table of Contents

Advertisement

Service Handbook OGB/OGS
Attention: The gas supply may not have any kinks
4.
Remove burner insert 6
Remove the aluminium tape from the insulation in the area of the convection
burner insert 6 (When removing the steam generator burner insert, this is not
necessary).
Push the insulation carefully aside (possibly using the cutter).
Unscrew the nut 7 on the flange.
Carefully remove the burner insert 6.
Replacing (Step-by-step Instructions)
Instructions:
1.
Check the burner insert before installing.
Check the heat electrode electrical circuit.
Check that there are no hairs (from the burner sock) between the burner and
the monitoring electrode.
The cable of the ionisations electrode must not touch the burner. Make sure
that for convection burner a distance of 2 cm between cable and burner tube
is ensured. On steam generator burners, this is not necessary.
2.
Install in reversed order.
Install the burner in reversed order step-by-step. (see removing instructions).
Attention: Always use new seals  13, 14, 15
Assembly advice:
Coat all the nuts with copper paste before installation.
Don't forget to reinstall the restriction flange 10 and two seals 13 between
burner fan and the burner insert.
3.
Test
Turn on the gas supply.
Switch on the power supply.
Test all connections for tightness (Gas detector or leak spray)
Start unit operation
After removing and replacing the burner, check the gas exhaust values (CO
less than 1000 ppm, CO
Handbook 6.25)
When the burner is running check all connections for tightness (Gas detector
or leak spray): now you can check the connections on the blower 4 and
burner insert 6!
AS/11-2011 Item 7016475
8% to 11% depending on gas type  see Service
2
6_23e_Removing and replacing the burners_c.doc
Page 2 / 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents