Convotherm OEB Series Service Handbook page 254

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
easy
OEB OES OGB OGS
touch
KD / 19.08.2009
Error
Error description
message
interruption
ID=2
E23.1
Steam generator
(sensor B4 in boiler )
ID=11
- short circuit to earth
E24.0
Bypass sensor (B5-
thermoelement)
ID=4
interruption
E24.1
Bypass sensor -
(B5 in the bypass
ID=13
pipe) short circuit to
earth
E25.0
Condenser sensor
(B3- thermoelement)
ID=3
interruption
E25.1
Condenser sensor -
(sensor B3 in
ID=12
condenser) short
circuit to earth
E26.0
Safety temperature
limiter (B8-
ID=1
thermoelement)
interruption
E26.1
Safety temperature
limiter - (B8 in boiler)
ID=10
short circuit to earth
E27.0
STL (B8-
thermoelement)
ID=19
excessive
temperature
(STL measures a
temp. >130° C in the
SG when SG heaters
switched on)
E29.0
Short circuit to earth
of a thermoelement
E29.1
CTS1 short circuit to
earth
ID=15
5_00e_Troubleshooting list and error messages - Electronics_h.doc
Possible cause or remedy
Steam generator sensor (B4) interrupted
(defective)
Thermoelement sensor (B4) has contact with
appliance housing due to boiler overheating
Steam generator sensor (B4) defective
Sensor wiring interrupted (plug X16 of the control
module)
Bypass sensor (B5) interrupted (defective)
Thermoelement sensor (B5) has contact with
appliance housing
Bypass sensor (B5) defective
Sensor wiring interrupted (plug X16 of the control
module)
Condenser sensor (B3) interrupted (defective)
Thermoelement sensor (B3) has contact with
appliance housing
Condenser sensor (B3) defective
Sensor wiring interrupted (plug X17 of the control
module)
STL (SG) sensor (B8) interrupted (defective)
STL (SG) Thermoelement sensor (B8) has contact
with appliance housing due to boiler overheating
STL (SG) sensor (B8) defective
Foaming in the steam generator when cooking (due to
e.g. wrong, non-original CONVOTHERM cleaning
agents)
Calcification of the steam generator
Boiling dry of the immersion heaters due to double
level sensor's short circuit to earth
A thermoelement sensor has contact with appliance
housing
Connection between sensor wire and sensor housing
Test individual sensors for short circuit to earth
(beginning with CTS)
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
Page 8 / 21