Service Handbook OEB/OES/OGB/OGS
Safety Advice for Service work
Attention – Lifting or sliding unit:
Avoid damaging the power, water and drainage connections when moving the
unit.
Make sure that the unit is secured against tilting or slipping while being
moved.
Observe the weight of the unit:
Electric units
CONVOTHERM OES / OEB 6.10: 170 kg
CONVOTHERM OES / OEB 6.20: 220 kg
CONVOTHERM OES / OEB10.10: 215 kg
CONVOTHERM OES / OEB10.20: 245 kg
CONVOTHERM OES / OEB12.20: 325* kg
CONVOTHERM OES / OEB20.10: 340* kg
CONVOTHERM OES / OEB20.20: 440* kg
* = incl. loading trolley
Attention – Working in the connection area of the unit:
Work in the connection area of the unit must be carried out by a qualified
electrician in accordance with the local power supply company regulations as
well as current EU regulations.
When working in the connection area, the unit main power supply must be
shut off (an all-pole isolation switch with a minimum contact opening of 3mm
must be located close to the unit) Make sure that the unit's power has indeed
been switched off!
After servicing, a final test, according to the local and current regulations, must
be performed.
Attention – working on the unit's gas system:
Working on the gas technology in a unit can only be performed by a qualified
installer from an authorized gas supplier.
Check all connection points outside and inside the unit for sealed tightness
(with a gas detector or leakage spray).
Attention: Do not spray leakage spray on electrical components of the
ignition and flame monitoring devices!
AS/11-2011
Gas units
CONVOTHERM OGS / OGB 6.10: 170 kg
CONVOTHERM OGS / OGB 6.20: 220 kg
CONVOTHERM OGS / OGB10.10: 215 kg
CONVOTHERM OGS / OGB10.20: 245 kg
CONVOTHERM OGS / OGB12.20: 325* kg
CONVOTHERM OGS / OGB20.10: 340* kg
CONVOTHERM OGS / OGB20.20: 440* kg
* = incl. loading trolley