Convotherm OEB Series Service Handbook page 116

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
O
O
O
O
E
Error-
E
E
G
G
message
T
B
S
B
S
   
Not
enough
cleaner
pressure
   
Fatal
IDM error
ID48
   
IDM error
Short cut:
CM = Control modul
SG = Steam generator
GM = Gas modul
ET = easyTOUCH
5_00e Troubleshooting list_L
Error description
Too little flow pressure
on the pressure switch
S2 (after 40 secs. still
below 0.1 bar)
No viable record in the
IDM module and
control module
Operating of the unit is
no longer possible.
IDM module error
Unit can be used
unrestricted.
OM = operating modul
FC = Frequency converter
FA = Flame Controller
13/27
possible cause or remedy
Cleaner level/nozzle flushing agent level in the canister
too low
Wrong pressure switch installed: (80, 120, 150,
200mbar)
Piping in the pump box is kinked
Suction hose not in the cleaner fluid / nozzle flushing
agent
Rotor nozzle worn or defective -> loses too much fluid in
the middle
Cleaner nozzle behind suction plate is loose or missing
Piping in the pump box leaking
Rinse pump / Cleaner pump without supply voltage
Rinse pump / Cleaner pump overheated
Rinse pump / Cleaner pump defective
When switching on and booting the appliance controller
finds no viable record either in the control module itself
or in the IDM
a) due to overvoltage record in the IDM was
destroyed
b) IDM module defective
c) contact problems of the X10 plug
When switching on and booting the appliance controller
finds no viable record in the IDM.
If there is a viable record in the CM itself, there is an
attempt to transfer this to the IDM. If this works, the error
disappears, if not, the error always appears briefly when
switching on
 fit new IDM
2013-01-30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents