Service manual OEB/OES/OGB/OGS
easy
OEB OES OGB OGS
touch
KD / 19.08.2009
Error
Error description
message
E05.8-2 No gas
E05.9-1 No gas
(only 20.10 / 20.20)
E05.9-2 No gas
(only 20.10 / 20.20)
E05.10
No gas
(from software 4.15)
ID=52
Wait 20 seconds, if
there is no "Flame
OK" or "Alarm
Signal"
E05.11
No gas
(from software 4.15)
ID=54
Wait 20 seconds, if
there is no "Flame
OK" or "Alarm
Signal"
E05.12
No gas
(from software 4.15)
ID=53
Wait 20 seconds, if
there is no "Flame
OK" or "Alarm
Signal"
E11.0
Oven sensor (B6
thermoelement)
ID=23
excessive
temperature
(temperature on the
sensor >300°C)
E12.1
Core temperature
sensor 1 - excessive
ID=25
temperature
E12.2
Core temperature
sensor 2 - excessive
ID=26
temperature
E12.3
Core temperature
sensor 3 - excessive
ID=27
temperature
E12.4
Core temperature
sensor 4 - excessive
ID=28
temperature
E13.0
Steam generator (B4
thermoelement)
5_00e_Troubleshooting list and error messages - Electronics_h.doc
Possible cause or remedy
Full load speed at the burner SG not reached
Possibly voltage supply disturbed
Full load speed at the burner HA2 not reached
PWM signal interrupted
Full load speed at the burner HA2 not reached
Possibly voltage supply disturbed
Interruption of Flame OK or Alarm Signal between
flame controller - control module HA1.
Check connection between FA and CM / GM:
CM (Control Module): for OGS 6.10 to OGS 12.20:
X14:1/2 and X15:12 (for appliances without GM)
GM (Gas Module): Plug X20:5/6 and X25:10
FA (Flame Controller): Terminals 1, 2, 5
Interruption of Flame OK or Alarm signal between
flame controller - SG control.
Check connection between FA and GM:
GM (Gas Module): Plug X21:4/5 and X25:11
FA (Flame Controller): Terminals 1, 2, 5
Interruption of Flame OK or Alarm signal between
flame controller - control module HA2.
Check connection between FA and GM:
GM (Gas Module): Plug X22:4/5 and X25:12
FA (Flame Controller): Terminals 1, 2, 5
Hot air contactors do not switch off (burnt together)
Motor not operating (e.g. because of 2 defective
microfuses F10.
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
Foaming in the steam generator when cooking (due to
e.g. wrong, non-original CONVOTHERM cleaning
Page 6 / 21