Service manual OEB/OES/OGB/OGS
OEB OES OGB OGS
KD / 19.08.2009
Error
Error description
message
E03.0-
Fan malfunction
0-0
(excessive
temperature in the
motor winding)
thermoprotection
contact has tripped
E03.0-
CrF
0-0
Charging switch
(ALTIVAR [41] display)
E03.0-
InF
0-0
Internal fault
(ALTIVAR [41] display)
E03.0-
ObF
0-0
Excess voltage at
end of process
(ALTIVAR [41] display)
OCF
E03.0-
0-0
Excess current
(ALTIVAR [41] display)
E03.0-
OHF
0-0
Converter
overloaded
(ALTIVAR [41] display)
E03.0-
OLC
0-0
Excess current
(ALTIVAR [41] display)
E03.0-
OLF
0-0
Motor overload
(ALTIVAR [41] display)
E03.0-
OSF
0-0
Excess voltage
(ALTIVAR [41] display)
E03.0-
SCF
0-0
Motor short circuit,
insulation fault
(ALTIVAR [41] display)
E03.0-
USF
0-0
Under voltage
(ALTIVAR [41] display)
Possible cause or remedy
Fan motor has excessive temperature in the winding
•
a) One phase is missing from the power connection
b) Fan motor is defective
c) One phase is not connected through from the
contactor
d) Microfuse F10 (6.3 A or 10 A for floor models)
has tripped
e) Thermoprotection contact in the motor winding
(bi-metallic strip) defective or interrupted
Replace the converter
•
Check the environment (electro magnetic
•
compatibility)
Replace the converter
•
Braking or driving load too strong
•
Moment of inertia too high or load too strong.
•
Check the motor /converter dimensioning / check
load
Mechanical blockage, check the mechanics
•
Check the motor load, converter and environment
•
ventilation. Wait for it to cool down before switching
on again.
Current strength above overload threshold value
•
Check mechanics (wear and tear, mechanical
•
steering heaviness, lubrication, obstructions,...)
Check the thermoprotection settings for the motor
•
and motor overload. Wait for it to cool down before
switching on again.
Check the mains voltage
•
Check connection cable between converter and
•
motor and the motor insulation
Check the mains voltage
•
5_00e_Troubleshooting list and error messages - Electronics_h.doc