Service manual OEB/OES/OGB/OGS
O
O
O
O
E
Error-
E
E
G
G
message
T
B
S
B
S
E03.32-
xxx-yyy
E03.128-
xxx-yyy
E03.zzz-
xxx-yyy
E04.xxx
ID36
E05.xxx
ID 52
injection
without
gas
modul
Units
with gas
modul:
ID52
5_00e Troubleshooting list_L
Error description
reporting a speed,
deleted from software
xxx
Just SAWI Frequency
converter
Error frequency
converter 2 (for
bottom motor)
Just SAWI Frequency
converter
Communication failure
between CM and GM
or between GM and
FC
Just SAWI Frequency
For an explanation of the parameter xxx-yyy-zzz see the end
converter
of 5.1 page 9
Other error variants
Auxiliary fan fault
Motor current too high
etc.: threshold of 1.5A
(V1-V2)
No gas (after 2 ignition
attempts no confirmed
gas flame)
INFO:
Compatibility between
SM and GM
SM Hardware Version
2 and higher / later.
GM Software Version
7 or higher / later
4/27
possible cause or remedy
FC dirty
For an explanation of the parameter xxx-yyy-zzz see the
end of 5.1 page 9
Mains voltage supply has faults, possibly also
undervoltage
Frequency converter defective
FC dirty
Wiring space temperature too high (but E02 is not being
displayed yet Check wiring space cooling
Check operation of auxiliary fan
Fan blocked or wrong motor
Motor defective
FC defective
For an explanation of the parameter xxx-yyy-zzz see the
end of 5.1 page 9
Check cable connection GM too FC
FC defective
GM defective
For an explanation of the parameter xxx-yyy-zzz see the
end of 5.1 page 9
Auxiliary fan defective
Auxiliary fan wiring interrupted
Auxiliary fan blocked
No gas or fault in burner system
Glow igniter defective (measure current > 1,3A)
Glow insert displaced in metal housing (replace glow
igniter)
Ionisation electrode defective
- Short circuit monitoring electrode (
observe ignition of the burner in the start phase;
if flame was present: monitoring
circuit is the cause!) Watch out for
short circuit between cable and housing in particular!
- Burner stocking braid has a short circuit to earth to
the ionisation electrode
- Ionisation electrode cable is resting on earth
(in the burner or on motor cover)
Air in gas pipe
Gas tap closed
2013-01-30