Convotherm OEB Series Service Handbook page 257

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
easy
OEB OES OGB OGS
touch
KD / 19.08.2009
Error
Error description
message
Fatal
No viable record in
IDM
the IDM module and
error
control module
ID=48
IDM
IDM module error
error
5_00e_Troubleshooting list and error messages - Electronics_h.doc
Possible cause or remedy
When switching on and booting the appliance
controller finds no viable record either in the control
module itself or in the IDM
a) due to overvoltage record in the IDM was
destroyed
b) IDM module defective
c) Contact problems of the X10 plug
When switching on and booting the appliance
controller finds no viable record in the IDM. If there
is a viable record in the CM itself, there is an
attempt to transfer this to the IDM. If this works, the
error disappears, if not, the error always appears
briefly when switching on
Fit new IDM