Error
Error description
message
E12.4
Core temperature
sensor 4 - excessive
ID=28
temperature
E13.0
Steam generator (B4
thermoelement)
Excessive
temperature (if
temperature
measured in the SG
>120°C)
E15.0
Condenser sensor
(B3- thermoelement)
ID=21
excessive
temperature
(if temperature in
the condenser
measured > 100°C)
E16
Demoisturisation
flap operating fault
(only 6.06)
E21.0
Oven sensor (B6-
thermoelement)
ID=5
interruption
E21.1
Oven sensor B6 (in
front of fan) - Short
ID=14
circuit to earth
E22.0
Core temperature
sensor
(B10- thermoelement)
interruption (if more
than 2 measuring
points are interrupted)
E22.1
CTS1 core
temperature sensor
ID=6
failure
(B10- thermoelement)
interruption
E22.2
CTS2 core
temperature sensor
ID=7
failure
(B10- thermoelement)
interruption
Possible cause or remedy
Temperature of CTS sensor already higher than the
maximum possible desired value (sensor not
inserted into food correctly)
Foaming in the steam generator when cooking (due to
e.g. wrong, non-original CONVOTHERM cleaning
agents)
Calcification of the steam generator
Boiling dry of the immersion heaters due to double
level sensor's short circuit to earth
Water reservoir in the condenser too hot:
a) Tap closed
b) Appliance connected to hot water
c) Solenoid valve "condenser cooling" defective
d) Coil from the solenoid "condenser cooling"
defective
e) Inlet filter in the solenoid valve contaminated
f) Quenching nozzle in the condenser/siphon blocked
Demoisturisation flap faulty
a) Stiff
b) Motor contact
c) Motor defective
d) Flap blocked
e) Cable defects (contact / motor)
Sensor wiring interrupted (plug X16 of the control
module)
Oven sensor (B6) interrupted (defective)
Thermoelement sensor (B6) has contact with
appliance housing
Thermoelement (B6) defective
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (defective)
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
defective)
thermoelements
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
defective)
thermoelements