Convotherm OEB Series Service Handbook page 109

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
O
O
O
O
E
Error-
E
E
G
G
message
T
B
S
B
S
   
E05.6-1
ID53
   
E05.6-2
ID53
   
E05.7.xxx
  
E05.8.xxx
   
E05.9.xxx
   
E05.10.x
ID52
   
E05.11.x
ID54
   
E05.12.x
ID53
    
E11.xxx
ID23
   
ID25
5_00e Troubleshooting list_L
Error description
No gas
(only 20.10 / 20.20)
No gas
(only 20.10 / 20.20)
No gas
No gas
No gas
(only 20.10 / 20.20)
No gas
xx
(from Software 4.15)
Wait 40 seconds, if
there is no 'Flame OK'
or 'Alarm Signal'
No gas
xx
(from Software 4.15)
Wait 40 seconds, if
there is no 'Flame OK'
or 'Alarm Signal'
No gas
xx
(from Software 4.15)
Wait 40 seconds, if
there is no 'Flame OK'
or 'Alarm Signal'
Oven sensor (B6
thermoelement)
excessive temperature
(Temperature on the
sensor >300°C)
Core Temperature
Probe 1 – Over
possible cause or remedy
Start speed at the burner HA2 not reached
 possibly voltage supply disturbed
Start speed at the burner HA2 not reached
 PWM signal interrupted
Start speed at the burner HA2 not reached
 possibly voltage supply disturbed
Full load speed at the burner HA1 not reached
 PWM signal interrupted
Full load speed at the burner HA1 not reached
 possibly voltage supply disturbed
Full load speed at the burner steam generator not
reached
 PWM signal interrupted
Full load speed at the burner steam generator not
reached
 possibly voltage supply disturbed
Full load speed at the burner HA2 not reached
 PWM signal interrupted
Full load speed at the burner HA2 not reached
 possibly voltage supply disturbed
Interruption of flame OK or Alarm Signal between flame
controller - control module HL1.
Check connection between FA and CM / GM:
CM: for OGS 6.10 to OGS 12.20: X14:1/2 and X15:12
(for units without GM)
GM: Plug X20:5/6 and X25:10
FA: Clamps 1, 2, 5
Interruption of Flame OK or Alarm signal between flame
controller - SG control.
Check connection between FA and GM:
GM: Plug X21:4/5 and X25:11
FA: Clamps 1, 2, 5
Interruption of Flame OK or Alarm signal between flame
controller - control module HL2.
Check connection between FA and GM:
GM: Plug X22:4/5 and X25:12
FA:Clamps 1, 2, 5
Hot air contactors do not switch off (burnt together)
Motor not operating (e.g. because of 2 defective
miniature fuses F10, not with the 6.06 as F10 protects
the CM).
CTC probe has temperature higher than the maximum
acceptable value (sensor not correctly inserted into the food
6/27
2013-01-30