6.5.5 Double safety thermostats B8 and B7.2 in gas units with blower burner

Instructions:
Slide both probes B8 and B7.2 together in the pipe above the burner chamber
of the steam generator (as far as they will go).
Fasten / secure the probes with heat resistant cable binders on the clamp.
1 = Steam generator
2 = Burner chamber of Steam-
generating burner
3 = Pipe for both
the safety thermostat probes
4 = Blower burner

6.5.6 Screw in probes B3, B4, B5 and oven probe B6

Notice:
When screwing the probes in and out, use a new graphite seal Part no. 6005260.
AS/11-2011
Screw in probe
Part no.: 5002100
6_05e_Probe assembly and replacing_b