Convotherm OEB Series Service Handbook page 249

Table of Contents

Advertisement

Service manual OEB/OES/OGB/OGS
easy
OEB OES OGB OGS
touch
KD / 19.08.2009
Error
Error description
message
E03.8-
Temperature of the
xxx-yyy
fan motor 2 (bottom)
too high
E03.16-
The speed sensor of
xxx-yyy
the fan motor 2
(bottom) is no longer
reporting a speed
E03.32-
Error frequency
xxx-yyy
converter 2 (for top
motor)
E03.128 Communication
failure between CM
and GM or between
GM and FC
5_00e_Troubleshooting list and error messages - Electronics_h.doc
Possible cause or remedy
displayed yet
Check wiring space cooling
Check operation of auxiliary fan
Fan blocked or wrong motor
Motor defective
FC defective
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1
Fan motor has excessive temperature in the
winding (over 165° C)
a) One phase is missing from the power connection
b) Fan motor is defective
c) One phase is not connected through from the
contactor
d) Microfuse F10 (6.3 A or 10 A for
floor models) has tripped
e) Thermoprotection contact in the motor winding
(bi-metallic strip) defective or interrupted
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1
Motor speed not reached
Speed sensor on the motor defective
Mains voltage supply has faults, possibly also
undervoltage
Frequency converter defective
FC dirty
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1
Mains voltage supply has faults, possibly also
undervoltage
Frequency converter defective
FC dirty
Wiring space temp. too high (but E02 is not being
displayed yet
Check wiring space cooling
Check operation of auxiliary fan
Fan blocked or wrong motor
Motor defective
FC defective
For an explanation of the parameter xxx-yyy-zzz
see the end of 5.1
Check cable connection GM to FC
FC defective
GM defective
For an explanation of the parameter xxx-yyy-zzz
page 12
page 12
page 12
page 12
Page 3 / 21